| Error Message/Symptom | FRU/Action |
|---|---|
| Bus Timeout NMI, | 1. System Board |
| Slot n . | |
| Type (S)hut off NMI, (R)eboot, | |
| other keys to continue. | |
| Configuration for slot n . | 1. Run Setup Utility. |
| Diskette drive failure | 1. See 'Diskette Drive Checkout' |
| Diskette drive x failure | 1. See 'Diskette Drive Checkout' |
| where x =0 or x =1. | |
| Diskette read failure | 1. Replace diskette with a bootable diskette and retry. |
| press F1 to retry boot (or may also say | |
| F2 for Setup Utility). | |
| Gate A20 failure | 1. System Board |
| Hard disk configuration error | 1. Correct the hard disk configuration. |
| Hard disk controller failure | 1. System Board |
| Hard Disk failure | 1. Hard Disk |
| Hard disk failure - | 1. Check drive selection in setup. |
| press F1 to retry boot | 2. Hard Disk. |
| (or may also say press F2 | |
| for Setup Utility). | |
| F2 to enter ROM-based SETUP | 1. Run Setup Utility. |
| 2. Verify Configuration. | |
| ID information mismatch for slot n | 1. Run Setup Utility. |
| Invalid configuration information. | 1. Run Setup Utility. |
| Internal cache test failed - | 1. Processor Card |
| cache is disabled. | 2. System Board |
| Keyboard clock line failure. | 1. Keyboard cable and Keyboard connection. |
| 2. System Board | |
| Keyboard controller failure. | 1. System Board |
| Keyboard data line failure. | 1. System Board |
| Keyboard is locked. | 1. Unlock the Keyboard |
| Keyboard stuck key failure. | 1. Locate and fix. |
| 2. Keyboard cable and Keyboard connection. | |
| 3. System Board | |
| Memory failure at hex-value, | 1. RAM Memory Board |
| read hex-value , expecting hex-value . | |
| No boot device available - | 1. Diskette |
| press F1 to reboot | 2. Diskette Drive |
| or press F2 for Setup Utility. | 3. Hard Disk |
| No boot sector on hard disk. | 1. Format the C drive. |
| Press F1 to reboot | |
| or F2 for Setup Utility. | |
| No fail safe timer NMI | 1. System Board |
| No software port NMI | 1. System Board |
| No timer tick interrupt | 1. System Board |
| Not a boot diskette - | 1. Replace diskette with a bootable diskette. |
| press F1 to reboot | |
| or F2 for Setup Utility | |
| Pointer device failure | 1. Check cable connections |
| 2. Keyboard (TrackPoint) | |
| 3. External Mouse | |
| Real time clock failure | 1. Run Setup Utility |
| Shutdown failure | 1. Power-off, Power-on, Retry |
| 2. System Board | |
| Time of day not set - | 1. Run Setup Utility |
| run SETUP program | |
| Timer 2 failure | 1. System Board |
| Unexpected HW interrupt at address | 1. System Board |
| Type (R)eboot, other keys to continue. | |
| Hardware problem. Not displayed | |
| if the extended interrupt handler | |
| is not enabled. | |
| Unexpected interrupt | 1. System Board |
| in protected mode | |
| Unexpected SW interrupt at address | 1. System Board |
| Type (R)eboot, other keys to continue. | |
| Error(s) in software program. | |
| Not displayed if the | |
| extended interrupt handler is not | |
| enabled. | |
| Unexpected type 02 interrupt | 1. System Board |
| at xxxxxh | |
| Type (S)hut off NMI, | |
| (R)eboot, other keys to continue. | |
| Parity error occurred. | |
| Cause undetermined. | |
| Unresolved BUS Timeout NMI, | 1. System Board |
| Type (S)hut off NMI, | 2. Processor Card |
| (R)eboot, other keys to continue. | |
| Parity error occurred. | |
| Cause undetermined. | |
| Unresolved memory parity error | 1. System Board |
| Type (S)hut off NMI, | 2. SO-DIMM |
| (R)eboot, other keys to continue. | 3. Optional Memory (8MB or 16MB Board) |
| Parity error occurred. | |
| Cause undetermined. | |
| xxxxx h Option ROM checksum failure | 1. Power-off, Power-on, Retry |
| where xxxxx h is the | 2. Peripheral Card |
| starting address of the option ROM |