Jumper Settings for TX98-3D/TX98
Internal CPU Speed (MHz) | External Bus Speed (MHz) | FQ3 | FQ2 | FQ1 | Frequency Ratio | BF2 | BF1 | BF0 |
100 | 66 | [1-2] | [1-2] | [1-2] | 1.5x | [1-2] | [1-2] | [1-2] |
120 | 60 | [1-2] | [1-2] | [2-3] | 2.0x | [1-2] | [1-2] | [2-3] |
133 | 66 | [1-2] | [1-2] | [1-2] | 2.0x | [1-2] | [1-2] | [2-3] |
150 | 60 | [1-2] | [1-2] | [2-3] | 2.5x | [1-2] | [2-3] | [2-3] |
166 | 66 | [1-2] | [1-2] | [1-2] | 2.5x | [1-2] | [2-3] | [2-3] |
200 | 66 | [1-2] | [1-2] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
233 | 66 | [1-2] | [1-2] | [1-2] | 3.5x | [1-2] | [1-2] | [1-2] |
FOR CYRIX/IBM 6x86/6x86MX/MII CPU
Internal CPU Speed (MHz) | External Bus Speed (MHz) | FQ3 | FQ2 | FQ1 | Frequency Ratio | BF2 | BF1 | BF0 |
P150+ | 60 | [1-2] | [1-2] | [2-3] | 2.0x | [1-2] | [1-2] | [2-3] |
P166+ | 66 | [1-2] | [1-2] | [1-2] | 2.0x | [1-2] | [1-2] | [2-3] |
PR200 | 75 | [1-2] | [2-3] | [1-2] | 2.0x | [1-2] | [1-2] | [2-3] |
PR233 | 66 | [1-2] | [1-2] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
PR233 | 75 | [1-2] | [2-3] | [1-2] | 2.5x | [1-2] | [2-3] | [2-3] |
PR266 | 66 | [1-2] | [1-2] | [1-2] | 3.5x | [1-2] | [1-2] | [1-2] |
PR266 | 83 | [2-3] | [1-2] | [2-3] | 2.5x | [1-2] | [2-3] | [2-3] |
PR300 | 66 | [1-2] | [1-2] | [1-2] | 3.5x | [1-2] | [1-2] | [1-2] |
PR300 | 75 | [1-2] | [2-3] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
PR333 | 66 | [1-2] | [1-2] | [1-2] | 4.0x | [2-3] | [1-2] | [2-3] |
PR333 | 75 | [1-2] | [2-3] | [1-2] | 3.5x | [1-2] | [1-2] | [1-2] |
PR333 | 83 | [2-3] | [1-2] | [2-3] | 3.0x | [1-2] | [2-3] | [1-2] |
FOR AMD-K5/K6/K6-2 CPU
Internal CPU Speed (MHz) | External Bus Speed (MHz) | FQ3 | FQ2 | FQ1 | Frequency Ratio | BF2 | BF1 | BF0 |
PR100 | 66 | [1-2] | [1-2] | [1-2] | 1.5x | [1-2] | [1-2] | [1-2] |
166 | 66 | [1-2] | [1-2] | [1-2] | 2.5x | [1-2] | [2-3] | [2-3] |
200 | 66 | [1-2] | [1-2] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
233 | 66 | [1-2] | [1-2] | [1-2] | 3.5x | [1-2] | [1-2] | [1-2] |
266 | 66 | [1-2] | [1-2] | [1-2] | 4.0x | [2-3] | [1-2] | [2-3] |
300 | 66 | [1-2] | [1-2] | [1-2] | 4.5x | [2-3] | [2-3] | [2-3] |
333 | 66 | [1-2] | [1-2] | [1-2] | 5.0x | [2-3] | [2-3] | [1-2] |
FOR IDT-C6 CPU
Internal CPU Speed (MHz) | External Bus Speed (MHz) | FQ3 | FQ2 | FQ1 | Frequency Ratio | BF2 | BF1 | BF0 |
150 | 50 | [2-3] | [2-3] | [2-3] | 3.0x | [1-2] | [2-3] | [1-2] |
150 | 75 | [1-2] | [2-3] | [1-2] | 2.0x | [1-2] | [1-2] | [2-3] |
180 | 60 | [1-2] | [1-2] | [2-3] | 3.0x | [1-2] | [2-3] | [1-2] |
200 | 66 | [1-2] | [1-2] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
255 | 75 | [1-2] | [2-3] | [1-2] | 3.0x | [1-2] | [2-3] | [1-2] |
CPU Voltage Selection
CPU Type | Voltage Requirements |
---|---|
Intel Pentium Cyrix/IBM M1 6x86 AMD K5 IDT-C6 |
3.4V(STD) / 3.5V(VRE) |
Intel Pentium with MMX Cyrix/IBM M1 6x86L |
2.8V |
Cryix/IBM 6x86MX AMD-K6-166, 200 |
2.9V |
AMD-K6-233 | 3.2V |
AMD-K6-266, 300, K6-2 | 2.2V |
CPU Core Voltage Table
Vcore | VID4 | VID3 | VID2 | VID1 | VID0 |
2.2V | [1-2] | [1-2] | [1-2] | [2-3] | [1-2] |
2.8V | [1-2] | [2-3] | [1-2] | [1-2] | [1-2] |
2.9V | [1-2] | [2-3] | [1-2] | [1-2] | [2-3] |
3.2V | [1-2] | [2-3] | [2-3] | [1-2] | [1-2] |
3.3V | [1-2] | [2-3] | [2-3] | [1-2] | [2-3] |
3.4V | [1-2] | [2-3] | [2-3] | [2-3] | [1-2] |
3.5V | [1-2] | [2-3] | [2-3] | [2-3] | [2-3] |
Special Function
Keys
Press the key "F" during power on to clear the CMOS
Press the
key "J" during power on to re-detect
the CPU
Copyright(c) 1998 Zida Technologies Limited. All Rights
Reserved.
Last Updated on 17
July 1998
Legal Notice