Jumper Settings for 6DXP
CPU Speed
Selection
CPU Speed (MHz) | External Bus (MHz) | JP4 | JP5 | JP15 | JP16 | Frequency Ratio | JP8 | JP9 | JP10 |
150 | 60 | [Short] | [Open] | [Short] | [Open] | 2.5x | [Open] | [Short] | [Short] |
166 | 66 | [Open] | [Short] | [Open] | [Short] | 2.5x | [Open] | [Short] | [Short] |
180 | 60 | [Short] | [Open] | [Short] | [Open] | 3x | [Short] | [Open] | [Short] |
200 | 66 | [Open] | [Short] | [Open] | [Short] | 3x | [Short] | [Open] | [Short] |
CPU Voltage
Selection
The CPU voltage is
automatically detected. No jumper setting is needed.
CMOS
Reset
If you want to reset the
CMOS data, please follow the procedures as below:
1. Switch off the power
supply of your system
2. Short jumper JP19
Description | JP19 |
Normal Operation | Open |
CMOS Reset | Short |
After CMOS reset, all data in CMOS will be lost. So
you need to re-enter the data again.
Copyright(c) 1998
Zida Technologies Limited. All Rights Reserved.
Last Updated on 23
June 98
Legal