ZIDA |
MANUAIS DE MOTHERBOARDS ZIDA |
Jumper Settings for 6ABX
CPU Speed (MHz) | External Bus Speed (MHz) | Frequency Ratio | JP3 | JP10 | JP9 | JP8 | JP7 |
233 | 66 | 3.5x | Close | Close | Close | Open | Open |
266 | 66 | 4x | Close | Close | Open | Close | Close |
300 | 66 | 4.5x | Close | Close | Open | Close | Open |
333 | 66 | 5x | Close | Close | Open | Open | Close |
350 | 100 | 3.5x | Open | Close | Close | Open | Open |
400 | 100 | 4x | Open | Close | Open | Close | Close |
450 | 100 | 4.5x | Open | Close | Open | Close | Open |
500 | 100 | 5x | Open | Close | Open | Open | Close |
CPU
Voltage Selection
The CPU voltage is automatically detected. No jumper
setting is needed.
CMOS Reset
If you want to reset the CMOS data, please follow the procedures as
below:
1. Switch off the power supply of your system
2. Set jumper JP2 to position 1-2
3. Then reinstall the jumper to position 2-3
Jumper | JP2 |
Normal | 1-2 |
Reset | 2-3 |
After CMOS
reset, all data in CMOS will be lost. So you need to re-enter the data again.
Celeron Support
For 6ABX, the jumper settings for Intel Celeron CPU are the same as
Pentium II.