ZIDA |
MANUAIS DE MOTHERBOARDS ZIDA |
Jumper Settings for 5DLX
5DLX provides two modes for Jumper
Settings: (1) Auto Jumper Mode; (2) Manual mode.
Auto Jumper Mode
An advanced technology eliminates the necessity for the user to be bored by
jumper settings on the mainboard. It is capable of detecting the CPU brand, and
setting the appropriate CPU core voltage and speed according to instructions
from the user through CMOS setup menu.
To enable Auto Jumper Mode, short JP6 to position (1-2).
Manual Mode
To enable Manual Mode, short JP6 to position (2-3) and follow the jumper table
below for necessary jumper settings for CPU installed.
FOR INTEL PENTIUM / PENTIUM WITH MMX CPU
Internal CPU Speed (MHz) | External Bus Speed (MHz) | FQ1 | FQ2 | FQ3 | Frequency Ratio | BF2 | BF1 | BF0 |
90 | 60 | 2-3 | 1-2 | 1-2 | 1.5x | 1-2 | 1-2 | 1-2 |
100 | 66 | 1-2 | 1-2 | 1-2 | 1.5x | 1-2 | 1-2 | 1-2 |
120 | 60 | 2-3 | 1-2 | 1-2 | 2.0x | 1-2 | 1-2 | 2-3 |
133 | 66 | 1-2 | 1-2 | 1-2 | 2.0x | 1-2 | 1-2 | 2-3 |
150 | 60 | 1-2 | 1-2 | 1-2 | 2.5x | 1-2 | 2-3 | 2-3 |
166 | 66 | 2-3 | 1-2 | 1-2 | 2.5x | 1-2 | 2-3 | 2-3 |
200 | 66 | 1-2 | 1-2 | 1-2 | 3.0x | 1-2 | 2-3 | 1-2 |
233 | 66 | 1-2 | 1-2 | 1-2 | 3.5x | 1-2 | 1-2 | 1-2 |
FOR CYRIX/IBM 6x86/6x86MX/MII CPU
Internal CPU Speed (MHz) | External Bus Speed (MHz) | FQ1 | FQ2 | FQ3 | Frequency Ratio | BF2 | BF1 | BF0 |
P150+ | 60 | 2-3 | 1-2 | 1-2 | 2.0x | 1-2 | 1-2 | 2-3 |
P166+ | 66 | 1-2 | 1-2 | 1-2 | 2.0x | 1-2 | 1-2 | 2-3 |
PR200 | 75 | 1-2 | 2-3 | 1-2 | 2.0x | 1-2 | 1-2 | 2-3 |
PR233 | 66 | 1-2 | 1-2 | 1-2 | 3.0x | 1-2 | 2-3 | 1-2 |
PR233 | 75 | 1-2 | 2-3 | 1-2 | 2.5x | 1-2 | 2-3 | 2-3 |
PR266 | 66 | 1-2 | 1-2 | 1-2 | 3.5x | 1-2 | 1-2 | 1-2 |
PR266 | 83 | 2-3 | 1-2 | 2-3 | 2.5x | 1-2 | 2-3 | 2-3 |
PR300 | 66 | 1-2 | 1-2 | 1-2 | 3.5x | 1-2 | 1-2 | 1-2 |
PR300 | 75 | 1-2 | 2-3 | 1-2 | 3.0x | 1-2 | 2-3 | 1-2 |
PR333 | 66 | 1-2 | 1-2 | 1-2 | 4.0x | 2-3 | 1-2 | 2-3 |
PR333 | 75 | 1-2 | 2-3 | 1-2 | 3.5x | 1-2 | 1-2 | 1-2 |
PR333 | 83 | 2-3 | 1-2 | 2-3 | 3.0x | 1-2 | 2-3 | 1-2 |
FOR AMD K5/K6/K6-2 CPU
Internal Speed (MHz) | External Speed (MHz) | FQ1 | FQ2 | FQ3 | Frequency Ratio | BF2 | BF1 | BF0 |
PR90 | 60 | 2-3 | 1-2 | 1-2 | 1.5x | 1-2 | 1-2 | 1-2 |
PR100 | 66 | 1-2 | 1-2 | 1-2 | 1.5x | 1-2 | 1-2 | 1-2 |
PR133 | 66 | 1-2 | 1-2 | 1-2 | 1.5x | 1-2 | 1-2 | 1-2 |
166 | 66 | 1-2 | 1-2 | 1-2 | 2.5x | 1-2 | 2-3 | 2-3 |
200 | 66 | 1-2 | 1-2 | 1-2 | 3.0x | 1-2 | 2-3 | 1-2 |
233 | 66 | 1-2 | 1-2 | 1-2 | 3.5x | 1-2 | 1-2 | 1-2 |
266 | 66 | 1-2 | 1-2 | 1-2 | 4.0x | 2-3 | 1-2 | 2-3 |
300 | 66 | 1-2 | 1-2 | 1-2 | 4.5x | 2-3 | 2-3 | 2-3 |
333 | 66 | 1-2 | 1-2 | 1-2 | 5.0x | 2-3 | 2-3 | 1-2 |
FOR IDT-C6
Internal CPU Speed (MHz) | External Bus Speed (MHz) | FQ1 | FQ2 | FQ3 | Frequency Ratio | BF2 | BF1 | BF0 |
150 | 50 | 2-3 | 2-3 | 2-3 | 3.0x | 1-2 | 2-3 | 1-2 |
150 | 75 | 1-2 | 2-3 | 1-2 | 2.0x | 1-2 | 1-2 | 2-3 |
180 | 60 | 2-3 | 1-2 | 1-2 | 3.0x | 1-2 | 2-3 | 1-2 |
200 | 66 | 1-2 | 1-2 | 1-2 | 3.0x | 1-2 | 2-3 | 1-2 |
225 | 75 | 1-2 | 2-3 | 1-2 | 3.0x | 1-2 | 2-3 | 1-2 |
CPU VOLTAGE SELECTION
CPU Type | Voltage Requirements |
Intel
Pentium P54C Cyrix / IBM 6x86, AMD-K5 IDT-C6 |
3.4V (STD) / 3.5V (VRE) |
Intel
Pentium with MMX Cyrix / IBM 6x86L |
2.8V |
Cyrix / IBM 6x86MX, K6-166/200 | 2.9V |
AMD-K6-233 | 3.2V |
AMD-K6-266, 300, K6-2 | 2.2V |
CPU Core Voltage Table
Vcore | VID4 | VID3 | VID2 | VID1 | VID0 |
2.2V | 1-2 | 1-2 | 1-2 | 2-3 | 1-2 |
2.8V | 1-2 | 2-3 | 1-2 | 1-2 | 1-2 |
2.9V | 1-2 | 2-3 | 1-2 | 1-2 | 2-3 |
3.2V | 1-2 | 2-3 | 2-3 | 1-2 | 1-2 |
3.3V | 1-2 | 2-3 | 2-3 | 1-2 | 2-3 |
3.4V | 1-2 | 2-3 | 2-3 | 2-3 | 1-2 |
3.5V | 1-2 | 2-3 | 2-3 | 2-3 | 2-3 |
Bus Frequency Ratio
Ratio | BF2 | BF1 | BF0 |
2.0x | 1-2 | 1-2 | 2-3 |
2.5x | 1-2 | 2-3 | 2-3 |
3.0x | 1-2 | 2-3 | 1-2 |
3.5x / 1.5x | 1-2 | 1-2 | 1-2 |
4.0x | 2-3 | 1-2 | 2-3 |
4.5x | 2-3 | 2-3 | 2-3 |
5.0x | 2-3 | 2-3 | 1-2 |
5.5x | 2-3 | 1-2 | 1-2 |
Special
Function Key
Press "F" during power on to clear the CMOS settings
Press "J" during power on to re-detect CPU installed in Auto
Jumper Mode.