Jumper Settings for 5DLX


5DLX provides two modes for Jumper Settings: (1) Auto Jumper Mode; (2) Manual mode.

Auto Jumper Mode
An advanced technology eliminates the necessity for the user to be bored by jumper settings on the mainboard. It is capable of detecting the CPU brand, and setting the appropriate CPU core voltage and speed according to instructions from the user through CMOS setup menu.

To enable Auto Jumper Mode, short JP6 to position (1-2).

Manual Mode
To enable Manual Mode, short JP6 to position (2-3) and follow the jumper table below for necessary jumper settings for CPU installed.

FOR INTEL PENTIUM / PENTIUM WITH MMX CPU

Internal CPU Speed (MHz) External Bus Speed (MHz) FQ1 FQ2 FQ3 Frequency Ratio BF2 BF1 BF0
90 60 2-3 1-2 1-2 1.5x 1-2 1-2 1-2
100 66 1-2 1-2 1-2 1.5x 1-2 1-2 1-2
120 60 2-3 1-2 1-2 2.0x 1-2 1-2 2-3
133 66 1-2 1-2 1-2 2.0x 1-2 1-2 2-3
150 60 1-2 1-2 1-2 2.5x 1-2 2-3 2-3
166 66 2-3 1-2 1-2 2.5x 1-2 2-3 2-3
200 66 1-2 1-2 1-2 3.0x 1-2 2-3 1-2
233 66 1-2 1-2 1-2 3.5x 1-2 1-2 1-2

FOR CYRIX/IBM 6x86/6x86MX/MII CPU

Internal CPU Speed (MHz) External Bus Speed (MHz) FQ1 FQ2 FQ3 Frequency Ratio BF2 BF1 BF0
P150+ 60 2-3 1-2 1-2 2.0x 1-2 1-2 2-3
P166+ 66 1-2 1-2 1-2 2.0x 1-2 1-2 2-3
PR200 75 1-2 2-3 1-2 2.0x 1-2 1-2 2-3
PR233 66 1-2 1-2 1-2 3.0x 1-2 2-3 1-2
PR233 75 1-2 2-3 1-2 2.5x 1-2 2-3 2-3
PR266 66 1-2 1-2 1-2 3.5x 1-2 1-2 1-2
PR266 83 2-3 1-2 2-3 2.5x 1-2 2-3 2-3
PR300 66 1-2 1-2 1-2 3.5x 1-2 1-2 1-2
PR300 75 1-2 2-3 1-2 3.0x 1-2 2-3 1-2
PR333 66 1-2 1-2 1-2 4.0x 2-3 1-2 2-3
PR333 75 1-2 2-3 1-2 3.5x 1-2 1-2 1-2
PR333 83 2-3 1-2 2-3 3.0x 1-2 2-3 1-2

FOR AMD K5/K6/K6-2 CPU

Internal CPU Speed (MHz) External Bus Speed (MHz) FQ1 FQ2 FQ3 Frequency Ratio BF2 BF1 BF0
PR90 60 2-3 1-2 1-2 1.5x 1-2 1-2 1-2
PR100 66 1-2 1-2 1-2 1.5x 1-2 1-2 1-2
PR133 66 1-2 1-2 1-2 1.5x 1-2 1-2 1-2
166 66 1-2 1-2 1-2 2.5x 1-2 2-3 2-3
200 66 1-2 1-2 1-2 3.0x 1-2 2-3 1-2
233 66 1-2 1-2 1-2 3.5x 1-2 1-2 1-2
266 66 1-2 1-2 1-2 4.0x 2-3 1-2 2-3
300 66 1-2 1-2 1-2 4.5x 2-3 2-3 2-3
333 66 1-2 1-2 1-2 5.0x 2-3 2-3 1-2

FOR IDT-C6

Internal CPU Speed (MHz) External Bus Speed (MHz) FQ1 FQ2 FQ3 Frequency Ratio BF2 BF1 BF0
150 50 2-3 2-3 2-3 3.0x 1-2 2-3 1-2
150 75 1-2 2-3 1-2 2.0x 1-2 1-2 2-3
180 60 2-3 1-2 1-2 3.0x 1-2 2-3 1-2
200 66 1-2 1-2 1-2 3.0x 1-2 2-3 1-2
225 75 1-2 2-3 1-2 3.0x 1-2 2-3 1-2


CPU VOLTAGE SELECTION

CPU Type Voltage Requirements
Intel Pentium P54C
Cyrix / IBM 6x86,
AMD-K5
IDT-C6
3.4V (STD) / 3.5V (VRE)
Intel Pentium with MMX
Cyrix / IBM 6x86L
2.8V
Cyrix / IBM 6x86MX, K6-166/200 2.9V
AMD-K6-233 3.2V
AMD-K6-266, 300, K6-2 2.2V

CPU Core Voltage Table

Vcore VID4 VID3 VID2 VID1 VID0
2.2V 1-2 1-2 1-2 2-3 1-2
2.8V 1-2 2-3 1-2 1-2 1-2
2.9V 1-2 2-3 1-2 1-2 2-3
3.2V 1-2 2-3 2-3 1-2 1-2
3.3V 1-2 2-3 2-3 1-2 2-3
3.4V 1-2 2-3 2-3 2-3 1-2
3.5V 1-2 2-3 2-3 2-3 2-3

Bus Frequency Ratio

Ratio BF2 BF1 BF0
2.0x 1-2 1-2 2-3
2.5x 1-2 2-3 2-3
3.0x 1-2 2-3 1-2
3.5x / 1.5x 1-2 1-2 1-2
4.0x 2-3 1-2 2-3
4.5x 2-3 2-3 2-3
5.0x 2-3 2-3 1-2
5.5x 2-3 1-2 1-2


Special Function Key
Press "F" during power on to clear the CMOS settings
Press "J" during power on to re-detect CPU installed in Auto Jumper Mode.


Tomato Logo
Copyright(c) 1998 Zida Technologies Limited. All Rights Reserved.
Last Updated on
17 July 98

Legal Notice