SUPER P6DBS JUMPER SETTINGS
- CPU
Settings: (If using dual processors, both processors must
have the same speed and processor
CPUID.)
CPU Core/Bus Ratio Jumper Settings |
Ratio |
JB1 |
JB2 |
JB3 |
JB4 |
X 3.0 |
ON |
OFF |
ON |
ON |
X 3.5 |
OFF |
OFF |
ON |
ON |
X 4.0 |
ON |
ON |
OFF |
ON |
X 4.5 |
OFF |
ON |
OFF |
ON |
X 5.0 |
ON |
OFF |
OFF |
ON |
X 5.5 |
OFF |
OFF |
OFF |
ON |
X 6.0 |
ON |
ON |
ON |
OFF |
Example:
For Pentium II 400MHz CPU:
bus speed = 100MHz,
Core/Bus Ratio = X 4.0
the jumper settings should be:
JP11:OFF,JB1:ON,JB2:ON,
JB3:OFF,JB4:ON
|
Bus Speed Selection (JP11) |
JP11 (2-pin jumper) |
JP11 (3-pin jumper) |
ON |
OFF (Default) |
OFF |
1-2 |
2-3 |
66 MHz |
Auto (determined by CPU 66/100 pin) |
100 MHz |
Auto (determined by CPU 66/100 pin) |
66 MHz |
- CMOS/Battery:
- JBT1:
CMOS Clear, pin 1-2:
Normal(default), pin 2-3: CMOS Clear (To clear CMOS needs to
disconnect AC power.)
- JBT2: Optional
External battery, pin1: +3V, pin2 and pin3: No
Connect, pin4: Ground
- Front
Control Panel:
- JF1:
- IDE
LED: pin1:+5V, pin2:HD Active, pin3:HD
Active, pin4:+5V
- Power
LED: pin5:Vcc +5V, pin6: Vcc +5V, pin7:
Ground
- Keylock: pin8: Keyboard
Inhibit, pin9:Ground
- Speaker:
pin10: Vcc +5V, pin11 and pin12: No
Connect, pin13:Speaker Data
- JF2:
- Infrared
Connector: pin1:Vcc +5V, pin2: Key, pin3: IRRX,
pin4:Ground, pin5:IRTX, pin6-pin8: No Connect
- Power-ON:
pin9: PW_ON, pin10: Ground, pin11:No
Connect
- Reset: pin12: Ground,
pin13:Reset
- SCSI:
- S_LED: SCSI LED
Connector, pin1 and pin4 :Vcc, pin2 and pin3: SCSI
LED# Signal
- JA5
& JA6: SCSI Termination, ON
(default): Terminated, OFF: Un-terminated
- Overheat/Thermal
Control:
- BZ_ON
(for PCB rev.2.00): Buzzer On,
ON(default): Enable On-board Buzzer (Turn on the buzzer when
overheat occurs), OFF: Disable On-board Buzzer
- JOH1: Overheat LED
Connector, pin1: Overheat Data, pin2: +12V
- Power On
Control:
- JP20: Power_ON
Control,
- pin 1-2:
Power Up Automatically With The First Time AC power
Applied
- pin 2-3
(default): Controlled By The Power_ON Jumper (JF2
pin9 and pin10).
- WOL:Wake-On-LAN
Connector, pin1: +5V Standby Power, pin2: Ground,
pin3:Wake Up Pulse
- Others:
- JL1: Chassis
Intrusion Connector, OFF: Default, ON: Intrusion
(pin1: Intrusion Input, pin2:Ground)
- Power_SEC
(for PCB rev.2.00): Extra Power Connector,
pin1-pin3: Ground, pin4 & pin5: +3.3V, pin6: +5V
- JP18
& JP16: Unused (OFF)
|