MS-5149

注意事項:

這裡所提供的各項BIOS以及驅動程式是專為微星產品量身打造的, 並不適用於其他家產品,使用於其他公司產品上而造成損壞,本公司 將不負賠償及維修責任.

 
 
AMI(R) BIOS REVISION HISTORY:
1. This is the AMI(R) BIOS release.
2. This BIOS fixes the following problems:
- The bios is NSTL Y2K compliant.
ai7a
1. This is an AMI(R) BIOS release.
2. This BIOS solves the following problems of the previous version:
- In Windows(R) 95, if the SUSPEND button is pressed twice, system will hang. - In Windows(R) 95, even if Power Management is enabled, the SUSPEND button will not appear.
- In Windows(R) 95, 3COM(R) 3C509B ISA PnP Network Card will have a warning (!) message, and will not function properly.
- When booting with 3COM(R) 3C590 PCI Network Card boot ROM, the message "Press H to boot from hard disk" will not appear.
- Intel(R) P54C-200 MHz CPU will sometimes be detected as 210 MHz during boot-up.
- With on-board 256K cache, adding a 256K cache module will cause the system to hang during boot-up.
- After performing FDISK in Windows(R) 95, DOS FDISK will recognize the primary partition as non-DOS and the partition size will be 2MB lesser.
- These problems have been fixed in AI78. 3. New Functions:
- The AMD(R) PR166 and 200 CPU is now supported.
- The AMD(R) K6-166 CPU is now supported.
- "Boot from CD-ROM" and "Windows(R) NT 4.0 Auto Installation" functions are now supported.
ai78
1. This is an AMI(R) BIOS release.
2. This BIOS solves the following problems of the previous version:
- It will take 13 seconds for the BIOS to show the screen message.For AI75, this has been reduced to 8 seconds.
- When using AMD(R) CPU and 512K cache is installed, only 256K is detected.
- If the boot sequence is set to "CDROM, C, A" and a non-bootable CD-ROM is in the drive, the system will hang-up upon boot-up.
- When using Mitsumi 6X CD-ROM and CTRL-ALT-DEL is pressed, the system will sometimes show "FDC Failure".
- If a CD-ROM is installed in 2nd channel, upon boot-up, the system will show "Press F1 to continue".
- If printer is set to 3BC, there will be a warning in Windows(R) 95.
- During Power Saving mode, when speaker is working and the green switch button is pressed, speaker will emit some noise. - All these problems have been fixed in AI75.
ai75
1. This is an AMI(R) BIOS release.
2. This BIOS solves the following problems of the previous version:
- Cyrix(R) P166+ CPU (133MHz) will sometimes show 150MHz.
- When "SDRAM RAS to CAS Delay" is set to "2 Clocks", system will hang up while booting.
- In Windows(R) 95, Supra Express Modem Card driver will not install properly.
- In Windows(R) 95, Realink LAN Card driver will not install properly.
- Hard Disk will enter Suspend Mode by itself.
- Using some VGA cards (esp. ATI Mach 64) with Viewsonic monitor, sometimes there is no display after software reset.
- Using Acer DCS Soundwaving Pro C-S509 with Crystal chipset PnP sound card will cause the system to hang up after warm reset. Furthermore, it will not work properly under Windows(R) 95.
- ISA Modem Card cannot use IRQ 9. (Basically, the application driver must support IRQ 9 to test this function.)
- "Boot sector virus protection" function will fail.
- Using Intel(R) 200MHz CPU with Hitachi 16MB (at SIMM1 and 2) and Hitachi 8MB SIMM (at SIMM3 and 4), system will hang up while booting. Exchanging 16MB and 8MB position is OK.
- System will sometimes show "Cache Bad" while booting.
- System will sometimes show "768K" or "Disable cache size" while booting.
- Using Adaptec PCI SCSI Card in Windows(R) 95, after the system is shutdown, cannot press CTRL-ALT-DEL to reboot.
- All the problems above were fixed in AI73.
ai73
This is the initial AMI(R) BIOS release.
ai71
AWARD(R) BIOS REVISION HISTORY:
1. This is an AWARD(R) BIOS release.
2. This BIOS solves the following problems of the previous version:
- The old BIOSes are not Year 2000 compliant. This BIOS is now Year 2000 compliant.
wi7c
1. This is an AWARD(R) BIOS release.
2. New Function:
- The new AMD(R) PR166 CPU is now supported.
wi7b
1. This is an AWARD(R) BIOS release.
2. This BIOS solves the following problems of the previous version:
- With Intel(R) 150MHz CPU, the system will sometimes hang during warm boot.
- Using single-sided + double sided EDO memory with 133MHz CPU, the system will sometimes hang during warm boot.
wi7a
1. This is an AWARD(R) BIOS release.
2. This BIOS is almost the same as WI77, except that in this BIOS, the default setting for the "USB Controller" has been set to Disabled.
wi78
1. This is an AWARD(R) BIOS release.
2. This BIOS solves the following problems of the previous version:
- Some CD-ROM's such as Goldstar, Panasonic, etc. were not auto-detected in Windows(R) 95.
- Using Cyrix(R) 6x86 CPU, the system will sometimes hang up on warm boot (pressing CTRL-ALT-DEL).
- The hard disk on 2nd channel will not power down in power saving mode.
- Using AHA-2940/3940 PCI SCSI controller will show some error messages in Windows(R) 95.
- System will sometimes hang up when CTRL-ALT-DEL is pressed.
- System will sometimes hang up at checkpoint C1 and C6 upon boot-up.
- All these problems were fixed in WI76.
wi77
1. This is an AWARD(R) BIOS release.
2. This BIOS provides better compatibility with IDE hard disks.
3. Th is BIOS includes EDO DRAM auto-table. In the old versions, the performance of EDO is the same as that of Fast Page memory.
wi74
This is the initial AWARD(R) BIOS release.
wi72


Copyright(C) by Micro-Star International All Rights Reserved(R)