MANUAIS DE MOTHERBOARDS JBOND |
PCI500C-A
1. CPU Jumper Settings
Intel Processor | J118 | J119 |
60MHz | ON | NC |
66MHz | NC | ON |
Note:
2. Clear CMOS Data Jumper Settings
Operating Mode |
J2 |
Normal Operating (default) | Open |
Clear CMOS Data | Short 1-2 while computer power turn OFF |
3. External Cache Memory Jumper Settings
Cache Size | J71 | J72 |
0K | 1-2 | 1-2 |
256K | 1-2 | 2-3 |
512K | 2-3 | 2-3 |
4. Support SIMM Module List
5. Local Bus Master Selection Jumper
Local Bus Master | J149 | J150 | J151 | J152 |
PCI Slot 0 | X | X | 2-3 | 2-3 |
PCI Slot 1 | 2-3 | 1-2 | X | X |
PCI Slot 2 (Default) | X | X | 1-2 | 1-2 |
SCSI (Default) | 1-2 | 2-3 | X | X |
6. On-board SCSI Jumper Settings
On-board SCSI | JP1 |
IRQ 9 | 1-2 |
IRQ 11 | 2-3 |
7. On-board SCSI Terminator Power Source Jumper Settings
Operating Mode | J123 |
System (Default) | ON |
Peripheral | NC |