Professional Workstation 8000

Configuring the System Board


Configuring the System Board
#
Item
Function
1 JP1 Used for installing an external battery to replace the real-time clock battery.
2 SW1 Used for enabling or disabling:
  1. Hot spare boot 
  2. Power-On Password 

Jumper (JP1)

JP1 pins: J1-J7; provide the pin settings required for installing an external battery. The factory (default) settings are indicated as marked
 
Jumper Settings (JP1) External Battery
Pins
Function
Description
1-4
Battery
External battery connection
5-6
Battery
External battery jumper
6-7
Battery
Internal battery jumper (Default)

Switch Module (SW1)

SW1 contains four switches: S1-S4. The table illustrates the switch settings for S1 (hot spare boot) and S2 (Power-On Password). S3 and S4 are reserved and must be OFF. The factory (default) settings are indicated as marked
 
 
SW1 Settings
Feature
Description
S1
S2
S3
S4
Hot Spare Boot Disabled OFF - OFF OFF
  Enabled (Default) ON - OFF OFF
Power-On Password Disabled - ON OFF OFF
  Enabled1 (Default) - OFF OFF OFF
Note1: Enabled - allows a password to be set. 

 