Deskpro 6000

Configuring System Board


Pentium P5 Jumpers

J-11
1 - 4 External Battery Connector
5 - 6 External Battery Jumper
6 - 7 Internal Battery Jumper
Switch Block SW1
Processor S1 S2 S3 S4
100 OFF OFF ON
120 * ON OFF OFF
133 * ON OFF ON
166 * ON ON ON
200 * OFF ON ON
*Power-On Password, ON = Disabled; OFF = Enabled
Default = OFF
Switch Block SW2
Upgrade Selected S1 S2 S3 S4
10 MB ON ON ON ON
100 MB* OFF OFF OFF OFF
*Requires Option Module
Top of Page

Pentium Pro Jumpers P6

 
E-2
1 - 4 External Battery Connector
5 - 6 External Battery Jumper
6 - 7 Internal Battery Jumper
Switch Block SW1 
Processor S1  S2  S3  S4  S5  S6 
180  ON/OFF OFF  ON  ON  OFF  ON 
200  ON/OFF ON  ON  ON OFF  ON 
NOTE: Power-on-Password (ON =Disable, OFF = Enable "default")
S2: ( ON=66MHz and OFF=60MHz Bus Freq.) 
Switch Block SW2
Upgrade Selected S1 S2 S3 S4
10 MB ON  ON  ON  ON 
100 MB* OFF  OFF  OFF  OFF
*Requires Option Module
Top of Page

Pentium MMX Jumpers

 
J-11
1 - 4 External Battery Connector
5 - 6 External Battery Jumper
6 - 7 Internal Battery Jumper
Switch Block SW1
Processor S1 S2 S3 S4
166 * ON ON ON
200 * OFF ON ON
233 * OFF OFF ON
*Power-On Password, ON = Disabled; OFF = Enabled
Default = OFF
Switch Block SW2
Upgrade Selected S1 S2 S3 S4
10 MB ON ON ON ON
100 MB* OFF OFF OFF OFF
*Requires Option Module
 
Switch Block SW2
Upgrade Selected S1 S2 S3 S4
10 MB ON ON ON ON
100 MB* OFF OFF OFF OFF
*Requires Option Module
Top of Page

PII (Config Code BPQ2, BPP2, BNC2)

 
E-2
1 - 4 External Battery Connector
5 - 6 External Battery Jumper
6 - 7 Internal Battery Jumper
SW1 Settings
Processor Speed S1 S2 S3 S4 S5 S6 S7
66/200 MHz * OFF ON ON ON OFF ON
66/233 MHz  * OFF ON ON ON OFF OFF
66/266 MHz * OFF ON ON OFF ON ON
*Power -On Password
ON = Disable; OFF = Enable; Default is OFF
Switch Block SW2
Upgrade Selected S1 S2 S3 S4
10 MB ON  ON  ON  ON 
100 MB* OFF  OFF  OFF  OFF
*Requires Option Module
Top of Page

PII (Except Config Codes BPP2, BNC2, BPQ2)

 
E50
Pins Function Description
1 - 2 Battery Internal Battery Jumper
2 - 3 Battery External Battery 
5 - 6 Clear CMOS* Relocate Battery Jumper and Return
9 - 12 Battery External Battery Connection
* Must also remove the AC power cord
SW1 Settings
Processor Speed S1 S2 S3 S4 S5 S6
66/233 MHz  * OFF OFF ON ON **
66/266 MHz * ON ON OFF ON **
66/300 MHz * ON OFF OFF ON **
66/333 MHz * OFF ON OFF ON **
*Power -On Password
ON = Disable; OFF = Enable; Default is OFF
**AC Cord Connection
OFF = Main P/S is OFF, Aux P/S is ON
ON = Main P/S is ON, Aux P/S is ON
Top of Page


This page was updated on June 02, 2002
Comments about this page
Privacy and Legal Statement