Deskpro 4000

Configuring System Board


Pentium P5 Jumpers

 
J-11
1 - 4 External Battery Connector
5 - 6 External Battery Jumper
6 - 7 Internal Battery Jumper
 
Switch Block SW1
Processor S1 S2 S3 S4
100 OFF OFF ON
120 * ON OFF OFF
133 * ON OFF ON
166 * ON ON ON
200 * OFF ON ON
*Power-On Password, ON = Disabled; OFF = Enabled
Default = OFF
 
Switch Block SW2
Upgrade Selected S1 S2 S3 S4
10 MB ON ON ON ON
100 MB* OFF OFF OFF OFF
*Requires Option Module
Top of Page

Pentium Pro Jumpers P6

 
E-2
1 - 4 External Battery Connector
5 - 6 External Battery Jumper
6 - 7 Internal Battery Jumper
 
Switch Block SW1 
Processor S1  S2  S3  S4  S5  S6 
180  ON/OFF OFF  ON  ON  OFF  ON 
200  ON/OFF ON  ON  ON  OFF  ON 
NOTE: Power-on-Password (ON =Disable, OFF = Enable "default")
S2: ( ON=66MHz and OFF=60MHz Bus Freq.) 
 
Switch Block SW2
Upgrade Selected S1 S2 S3 S4
10 MB ON  ON  ON  ON 
100 MB* OFF  OFF  OFF  OFF
*Requires Option Module

Top of Page

Pentium MMX Jumpers

E - 50
Pins Function Description
1 - 2 Battery Internal Battery Jumper
2 - 3 Battery External Battery 
5 - 6 Clear CMOS* Relocate Battery Jumper and Return
9 - 12 Battery External Battery Connection
* Must also remove the AC power cord
 
Switch Block SW1
Processor S1 S2 S3 S4 S5 S6
166 * ON ON X ON **
200 * OFF ON X ON **
233 * OFF OFF X ON **
*Power-On Password, ON = Disabled; OFF = Enabled
Default = OFF
**AC Cord Connection
OFF = Main P/S is OFF, Aux P/S is ON
ON = Main P/S is ON, Aux P/S is ON
Disabling Power-On Password
The Power-On Password feature is enabled or disabled by moving the SW1 position on located on the system board.
Clearing Configuration and Password
The computer's configuration (CMOS) may occasionally be corrupted. When it does, it is necessary to clear the CMOS memory.
To clear and reset the configuration perform the following procedure:
  1. Unplug the power cord from the unit and remove the cover.
  2. Remove the E50 jumper from pins 1 and 2 and place on pins 5 and 6.
  3. Replace the E50 jumper on pins 1 and 2. 
When jumper E50 is removed, the password becomes invalid because the password is stored in the configuration memory. You will need to reset the password.
Changing the Real-Time Clock (RTC) Battery
When installing the replacement RTC Battery, the battery connector is keyed and should be connected to the pins on the E9 battery header connector.

Top of Page

PII (Config Code BPQ2, BPP2, BNC2)

 
E-2
1 - 4 External Battery Connector
5 - 6 External Battery Jumper
6 - 7 Internal Battery Jumper
 
SW1 Settings
Processor Speed S1 S2 S3 S4 S5 S6 S7
66/200 MHz * OFF ON ON ON OFF ON
66/233 MHz  * OFF ON ON ON OFF OFF
66/266 MHz * OFF ON ON OFF ON ON
*Power -On Password
ON = Disable; OFF = Enable; Default is OFF
 
Switch Block SW2
Upgrade Selected S1 S2 S3 S4
10 MB ON  ON  ON  ON 
100 MB* OFF  OFF  OFF  OFF
*Requires Option Module

Top of Page

PII (Except Config Codes BPP2, BNC2, BPQ2)

 
E50
Pins Function Description
1 - 2 Battery Internal Battery Jumper
2 - 3 Battery External Battery 
5 - 6 Clear CMOS* Relocate Battery Jumper and Return
9 - 12 Battery External Battery Connection
* Must also remove the AC power cord
 
SW1 Settings
Processor Speed S1 S2 S3 S4 S5 S6
66/233 MHz  * OFF OFF ON ON **
66/266 MHz * ON ON OFF ON **
66/300 MHz * ON OFF OFF ON **
66/333 MHz * OFF ON OFF ON **
*Power -On Password
ON = Disable; OFF = Enable; Default is OFF
**AC Cord Connection
OFF = Main P/S is OFF, Aux P/S is ON
ON = Main P/S is ON, Aux P/S is ON
Top of Page


This page was updated on June 02, 2002
Comments about this page
Privacy and Legal Statement