MANUAIS DE MOTHERBOARDS BIOTEQ |
MB-14XXUCV
JUMPER | 32K | 64K | 128K | 256K | 256K |
JP5 | 2-3 CLOSE | 1-2 CLOSE | 2-3 CLOSE | 1-2 CLOSE | 1-2 CLOSE |
JP6 | OPEN | OPEN | 2-3 CLOSE | 1-2 CLOSE | 1-2 CLOSE |
JP7 | OPEN | OPEN | CLOSE | CLOSE | CLOSE |
JP9 | OPEN | CLOSE | CLOSE | CLOSE | CLOSE |
JP10 | OPEN | OPEN | OPEN | 2-3 CLOSE | 1-2 CLOSE |
Tag ram | 8k x 8 | 8k x 8 | 8k x 8 | 32k x8 | 16k x 8 * |
* The main board can support TAG RAM:16k x 8 on condition the title on board is "MB-1433/50UVC-A"
PCB VER:1.1"Or later.
JP 3 Clear BIOS Password
POWER OFF --> JP3 CLOSED --> POWER ON --> AFTER MEM COUNT,POWER OFF
--> JP3 OPEN --> POWER ON --> RESET YOUR DESIRED PASSWORD.
JP 8 For external battery : Take off JP8 , Connect on PIN 1 and 4 a 6 Volt External Battery
1=+
4=-
Function 2 : CMOS DISCHARGE
2-3 Closed : To maintain setup and extended setup data in CMOS for normal funtion.
3-4 Closed : To clear CMOS setup memory, if there has been any inappropriate operation incurring the system is failure.
JP 11 Power Good Select.
1-2 Closed : For power supply power good
2-3 Closed : For on board power good signal.
JP 12 Cpu Type Select.
1-2 Closed : One CPU on board(PQFP ot PGA)
203 Closed : Two CPU’s on board (enable PGA and Disable PQFP)
JP 14 Monitor Type Select
1-2 closed : MONO
2-3 closed : COLOR
Jp16,Jp17 CPU Type Select ( See Below)
CPU TYPE | JP16 | JP17 | |
P24T/486DX/DX2 | 1-2 CLOSED | 1-2, 3-4 CLOSED | |
486SX/CX 486S | OPEN | 2-3 CLOSED | |
487SX/486-OVERDRIVE | 2-3 CLOSED | 1-2, 3-4 CLOSED |
JP34: OPEN, FOR CYRIX CX486DX CPU
JP34: CLOSE, FOR CYRIX CX486DX2 CPU
(PCB MB-1433UCV-D VER.X PROVIDES JP 34
JP 19 Vesa Bus Adress Sync/Acync Select
1-2 Closed : Asynchronous Mode ( For CPU speed 40/50 Mhz Only)
2-3 Closed : Synchonous Mode
JP 20 Vesa Bus Data Sync/Async Select
1-2 Closed : Synchonous Mode
2-3 Closed : Asynchonous Mode
Jp21,JP22,JP23,JP27 CPU Clock Select ( See table Below)
CPU CLOCK | JP21 | JP22 | JP23 | JP27 |
25MHZ
DX2-50 ONLY |
CLOSED | OPEN | CLOSED | OPEN |
33 MHZ
DX2-66MHZ |
CLOSED | CLOSED | OPEN | OPEN |
40 MHZ | OPEN | OPEN | CLOSED | CLOSED |
50 MHZ | OPEN | CLOSED | OPEN | CLOSED |
JP 25 Vesa Bus(SLOTV2) Clock Select
1-2 Closed : Synchronous mode
2-3 Closed : Asynchronous mode
JP26 Vesa Bus(SLOTV1) Clock Select
1-2 Closed : Synchronous mode
2-3 Closed : Asynchronous mode
JP28 Add-On Card Select
1-2 Closed : Normal operation
2-3 Closed : Weitek Power 9000 VGA card
JP29 Vesa Bus(SLOTV3) Clock Select
1-2 Closed : Synchronous mode
2-3 Closed : Asynchronous mode
JP 30 Vesa Bus(SLOTV2 & SLOTV3) Clock Select
1-2 Closed : Synchronous Mode (NOTE : JP25 Must Be Open)