MANUAIS DE MOTHERBOARDS BIOTEQ |
MB-M5TTB
JUMPERS SETTING
A: JP6 CMOS function selection
JP6 |
assignment |
1-2 closed |
normal operation |
2-3 closed |
clear CMOS data |
open |
onboard battery disabled |
Note: Please follow the procedure as below to clear BIOS password if your password is lost or forgotten.
power off -> JP6(2-3) closed -> JP6(1-2) closed -> power on
-> reset your desired password
CPU INSTALLATION/ JUMPER SETTING
(A) JP16 CPU VOLTAGE SELECTION
CPU type |
JP16 |
CPU voltage |
|
CORE |
I/O |
||
single voltage |
1-2 open |
3.5V |
3.5V |
dual voltage |
1-2 open |
2.1V |
3.3V |
1-2 closed |
2.2V |
3.3V |
|
1-2 open |
2.8V |
3.3V |
|
1-2 closed |
2.9V |
3.3V |
|
1-2 open |
3.2V |
3.3V |
|
1-2 closed |
3.3V |
3.3V |
(B) JP2,JP13 CPU clock selection
a: INTEL CPU
CPU speed |
bus clock
& |
JP2 |
JP2 |
JP2 |
JP13 |
JP13 |
JP13 |
90MHz |
60MHz x 1.5 |
open |
closed |
closed |
open |
open |
open |
100MHz |
66MHz x 1.5 |
closed |
open |
closed |
open |
open |
open |
120MHz |
60MHz x 2 |
open |
closed |
closed |
closed |
open |
open |
133MHz |
66MHz x 2 |
closed |
open |
closed |
closed |
open |
open |
150MHz |
60MHz x 2.5 |
open |
closed |
closed |
closed |
closed |
open |
166MHz |
66MHz x 2.5 |
closed |
open |
closed |
closed |
closed |
open |
200MHz |
66MHz x 3 |
closed |
open |
closed |
open |
closed |
open |
233MHz |
66MHz x 3.5 |
closed |
open |
closed |
open |
open |
open |
b: CYRIX 6x86 tm /6x86L tm CPU
CPU speed |
bus clock
& |
JP2 |
JP2 |
JP2 |
JP13 |
JP13 |
JP13 |
PR-150+ |
60MHz x 2 |
open |
closed |
closed |
closed |
open |
open |
PR-166+ |
66MHz x 2 |
closed |
open |
closed |
closed |
open |
open |
PR-200+ |
75MHz x 2 |
open |
closed |
open |
closed |
open |
open |
c: CYRIX 6x86MX tm CPU
CPU speed |
bus clock
& |
JP2 |
JP2 |
JP2 |
JP13 |
JP13 |
JP13 |
PR-150+ |
60MHz x 2 |
open |
closed |
closed |
closed |
open |
open |
PR-166+ |
66MHz x 2 |
closed |
open |
closed |
closed |
open |
open |
PR-166+ |
60MHz x 2.5 |
open |
closed |
closed |
closed |
closed |
open |
PR-200+ |
75MHz x 2 |
open |
closed |
open |
closed |
open |
open |
PR-200+ |
66MHz x 2.5 |
closed |
open |
closed |
closed |
closed |
open |
PR-200+ |
60MHz x 3 |
open |
closed |
closed |
open |
closed |
open |
PR-233+ |
75MHz x 2.5 |
open |
closed |
open |
closed |
closed |
open |
PR-233+ |
66MHz x 3 |
closed |
open |
closed |
open |
closed |
open |
PR-266+ |
66MHz x 3.5 |
closed |
open |
closed |
open |
open |
open |
PR-266+ |
75MHz x 3 |
open |
closed |
open |
open |
closed |
open |
d: AMD-K5 tm CPU
CPU speed |
JP2(1-2) |
JP2(3-4) |
JP2(5-6) |
JP13(1-2) |
JP13(3-4) |
JP13(5-6) |
PR-90 |
open |
closed |
closed |
open |
open |
open |
PR-100 |
closed |
open |
closed |
open |
open |
open |
PR-120 |
open |
closed |
closed |
closed |
open |
open |
PR-133 |
closed |
open |
closed |
closed |
open |
open |
PR-166 |
closed |
open |
closed |
closed |
closed |
open |
PR-200 |
closed |
open |
closed |
open |
closed |
open |
e: AMD-K6 tm CPU
CPU speed |
JP2(1-2) |
JP2(3-4) |
JP2(5-6) |
JP13(1-2) |
JP13(3-4) |
JP13(5-6) |
PR2-166 |
closed |
open |
closed |
closed |
closed |
open |
PR2-200 |
closed |
open |
closed |
open |
closed |
open |
PR2-233 |
closed |
open |
closed |
open |
open |
open |
CONNECTORS
A: J15
pin |
assignment |
function |
pin |
assignment |
function |
1 |
speaker |
speaker |
14 |
+5V |
VCC ground |
2 |
NC |
15 |
ground |
VCC ground |
|
3 |
ground |
16 |
no connection |
NC |
|
4 |
+5V |
17 |
green control |
green switch |
|
5 |
power LED (+) |
power LED |
18 |
ground |
green switch |
6 |
no connection |
19 |
no connection |
NC |
|
7 |
ground |
20 |
HDD LED(-) |
HDD LED |
|
8 |
NC |
21 |
HDD LED(+) |
HDD LED |
|
9 |
ground |
22 |
+5V |
IrDA connector |
|
10 |
power switch |
ATX power |
23 |
no connection |
IrDA connector |
11 |
standby voltage |
ATX power |
24 |
IRRX |
IrDA connector |
12 |
reset control |
reset |
25 |
ground |
IrDA connector |
13 |
ground |
reset |
26 |
IRTX |
IrDA connector |
B: J14 CPU cooling fan power connector
pin no. |
assignment |
3 |
fan RPM signal input (optional) |
2 |
ground |
1 |
+12V |
C: J18 Wake-On LAN Header
pin no. |
assignment |
1 |
wakeup signal input |
2 |
ground |
3 |
standby voltage (+5V) |
J19 ring-in resume on modem card (internal modem)
pin no. |
assignment |
1 |
ring-in signal input |
2 |
ground |
3 |
no connection |
D: JP15 ring-in resume selection (for external modem)
JP15 |
assignment |
1-2 closed |
ring-in on com 1/3 |
2-3 closed |
ring-in on com 2/4 |