MANUAIS DE MOTHERBOARDS BIOTEQ |
MB-M5ATA
JUMPER SETTING
A: JP4 CMOS function selection
JP4 |
assignment |
closed |
normal operation |
closed |
clear CMOS data |
open |
onboard battery disabled |
Note: Please follow the procedure as below to clear BIOS password if your password is lost or forgotten.
power off -> JP(2-3)closed -> JP4(1-2)closed -> power on -> reset your desired password
CPU INSTALLATION JUMPER SETTING
A: JP7 CPU voltage selection
CPU type |
CPU voltage |
JP7 |
|
CORE |
I/O |
||
single voltage |
3.5V |
3.5V |
1-2 closed |
dual voltage |
2.8V |
3.3V |
1-2 closed |
2.9V |
3.3V |
1-2 open |
|
3.1V |
3.3V |
1-2 open |
|
3.2V |
3.3V |
1-2 closed |
|
3.3V |
3.3V |
1-2 open |
B: JP9,JP6 CPU clock selection
(a) INTEL CPU
CPU speed |
bus clock |
JP9 |
JP9 |
JP9 |
JP6 |
JP6 |
JP6 |
90MHz |
60MHz x 1.5 |
open |
closed |
closed |
open |
open |
open |
100MHz |
66MHz x 1.5 |
closed |
open |
closed |
open |
open |
open |
120MHz |
60MHz x 2 |
open |
closed |
closed |
closed |
open |
open |
133MHz |
66MHz x 2 |
closed |
open |
closed |
closed |
open |
open |
150MHz |
60MHz x 2.5 |
open |
closed |
closed |
closed |
closed |
open |
166MHz |
66MHz x 2.5 |
closed |
open |
closed |
closed |
closed |
open |
200MHz |
66MHz x 3 |
closed |
open |
closed |
open |
closed |
open |
233MHz |
66MHz x 3.5 |
closed |
open |
closed |
open |
open |
open |
(b) CYRIX 6x86 tm / 6x86L tm CPU
CPU speed |
bus clock |
JP9 |
JP9 |
JP6 |
JP6 |
JP6 |
JP |
PR-150+ |
60MHz x 2 |
open |
closed |
closed |
closed |
open |
open |
PR-166+ |
66MHz x 2 |
closed |
open |
closed |
closed |
open |
open |
PR-200+ |
75MHz x 2 |
open |
open |
open |
closed |
open |
open |
(c) CYRIX 6x86 tm / 6x86L tm CPU
CPU speed |
bus clock |
JP9 |
JP9 |
JP9 |
JP6 |
JP6 |
JP6 |
PR-150+ |
60MHz x 2 |
open |
closed |
closed |
closed |
open |
open |
PR-166+ |
66MHz x 2 |
closed |
open |
closed |
closed |
open |
open |
PR-200+ |
75MHz x 2 |
open |
closed |
open |
closed |
open |
open |
PR-166+ |
60MHz x 2.5 |
open |
closed |
closed |
closed |
closed |
open |
PR-200 |
66MHz x 2.5 |
closed |
open |
closed |
closed |
closed |
open |
PR-200+ |
60MHz x 3 |
open |
closed |
closed |
open |
closed |
open |
PR-233+ |
75MHz x 2.5 |
open |
closed |
open |
closed |
closed |
open |
PR-233 |
66MHz x 3 |
closed |
open |
closed |
open |
closed |
open |
PR-266+ |
66MHz x 3.5 |
closed |
open |
closed |
open |
open |
open |
PR-266+ |
75MHz x 3 |
open |
closed |
open |
open |
closed |
open |
Note: Some add on cards may not support 37.5 MHz PCI bus
speed when CPU
bus is clock running at 75 MHz.
(d) AMD-K5 tm CPU
CPU speed |
JP9 |
JP9 |
JP9 |
JP6 |
JP6 |
JP6 |
PR-90 |
open |
closed |
closed |
open |
open |
open |
PR-100 |
closed |
open |
closed |
open |
open |
open |
PR-120 |
open |
closed |
closed |
closed |
open |
open |
PR-133 |
closed |
open |
closed |
closed |
open |
open |
PR-166 |
closed |
open |
closed |
closed |
closed |
open |
PR-200 |
closed |
open |
closed |
open |
closed |
open |
(e) AMD-K6 tm CPU
CPU speed |
JP9 |
JP9 |
JP9 |
JP6 |
JP6 |
JP6 |
PR2-166 |
closed |
open |
closed |
closed |
closed |
open |
PR2-200 |
closed |
open |
closed |
open |
closed |
open |
PR2-233 |
closed |
open |
closed |
open |
open |
open |
CONNECTORS
(a) J14
pin no |
assignment |
function |
pin no |
assignment |
function |
1 |
speaker |
speaker |
14 |
+5V |
VCC |
2 |
NC |
15 |
ground |
VCC |
|
3 |
ground |
16 |
no connection |
NC |
|
4 |
+5V |
speaker |
17 |
green control |
green switch |
5 |
power LED(+) |
power LED |
18 |
ground |
green switch |
6 |
no connection |
19 |
no connection |
NC |
|
7 |
ground |
20 |
HDD LED (-) |
HDD LED |
|
8 |
key lock |
21 |
HDD LED (+) |
HDD LED |
|
9 |
ground |
22 |
+5V |
IrDA |
|
10 |
power switch |
ATX power |
23 |
no connection |
IrDA |
11 |
standby voltage |
24 |
IRRX |
IrDA |
|
12 |
reset control |
reset |
25 |
ground |
IrDA |
13 |
ground |
26 |
IRTX |
IrDA |
(b) J2 PS/ 2 mouse cable connector
pin no |
assignment |
1 |
mouse data |
2 |
no connection |
3 |
ground |
4 |
+5V |
5 |
mouse clock |
(c) J13 U.S.B. connector
pin no |
assignment |
pin no |
assignment |
A1 |
+5V |
B5 |
no connection |
A2 |
port 1 negative data |
B4 |
ground |
A3 |
port 1 positive data |
B3 |
port 2 positive data |
A4 |
ground |
B2 |
port 2 negative data |
A5 |
no connection |
B1 |
+5V |
(d) J15 CPU cooling fan power connector (optional)
pin no |
assignment |
1 |
ground |
2 |
+12V |