MANUAIS DE MOTHERBOARDS BIOTEQ |
MB-14XXUTI
MB SPECIFICATIONS
486 ISA bus MB NON CACHE W/AMI BIOS
Green mode selection via hardware or software
Supports UMC 486SX/DX CPU
Supports 5V CPU
Provides 237-pin PGA/ZIF Socket (optional)
Supports DRAM memory up to 64MB on board
Provides memory sockets as follow
30 pin SIMM socket X 4 pcs
72 pin SIMM socket X 1 Pcs
Supports PAGE-mode/80ns DRAM
Provides 5 pcs 98-pin slots and 1 pcs 62-pin slot (5 isa 16 bits , 1 8 bits slot)
Dimension : 17cm x 22cm
Jumpersettings
JP 1 : Function 1
external battery :
(+) pin 1
(-) pin 4
How to install an external battery on board.
Step 1 : Turn off power
Step 2 : Take off the cap of JP 1 on board
Step 3 : Insert the connector of the external battery to JP1
JP 2 : Function 2 CMOS Discharge
(1-2) Closed : To maintain set-up and extended setup data in CMOS for normal function.(default)
(3-4) Closed : To clear original CMOS setup memory, if inapproptriate operation incurring that caused system failure.
JP 2, JP 3 CPU Type Select
JP 2 Closed : 486SX
JP 3 Closed : 486DX
JP 4,5,6 CPU Clock Select
Jumper No. |
25 Mhz |
33 Mhz |
40 Mhz |
50 Mhz |
JP 4 |
CLOSED |
CLOSED |
CLOSED |
OPEN |
JP 5 |
OPEN |
CLOSED |
CLOSED |
OPEN |
JP 6 |
OPEN |
CLOSED |
OPEN |
CLOSED |
JP 7,8 CPU Package Select
JP 7 and JP 8 Closed - PQFP Selected.
JP 7 and JP 8 Open - PGA
JP 9 Suspend LED Connector
JP10 Hardware Suspend Switch
JP 11 Reset Switch
JP 13 Turbo Led Connector
JP 14 Keylock Select
JP 15 Speaker Connector
JP 16 Keylock Connector