MANUAIS DE MOTHERBOARDS BIOTEQ |
MB-8500TTD
JUMPERS SETTING
JP3 CMOS function selection
JP3 |
assignment |
1-2 closed |
normal operation |
2-3 closed |
clear CMOS data |
open |
onboard battery disabled |
Note: please follow the procedure as below to clear BIOS
password if your password
is lost or forgotten.
power off -> JP3 (2-3) closed -> JP3(1-2) closed -> power on -> reset your desired password
CPU INSTALLATION / JUMPER SETTING
A: JP7,JP8 CPU voltage
CPU type |
JP7 |
JP8 |
CPU voltage |
|
core |
I/O |
|||
single voltage |
1-2 open |
1-2 closed |
3.5V |
3.5V |
dual voltage |
1-2 open |
1-2 open |
2.8V |
3.4V |
1-2 closed |
1-2 open |
2.9V |
3.4V |
|
1-2 open |
1-2 open |
3.2V |
3.4V |
B: JP11,JP9 CPU clock selection
a: INTEL CPU
CPU speed |
bus clock& |
JP11 |
JP11 |
JP11 |
JP9 |
JP9 |
90MHz |
60MHz x 1.5 |
open |
closed |
closed |
open |
open |
100MHz |
66MHz x 1.5 |
closed |
open |
closed |
open |
open |
120MHz |
60MHz x 2 |
open |
closed |
closed |
closed |
open |
133MHz |
66MHz x 2 |
closed |
open |
closed |
closed |
open |
150MHz |
60MHz x 2.5 |
open |
closed |
closed |
closed |
closed |
166MHz |
66MHz x 2.5 |
closed |
open |
closed |
closed |
closed |
200MHz |
66MHz x 3 |
closed |
open |
closed |
open |
closed |
233MHz |
66MHz x 3.5 |
closed |
open |
closed |
open |
open |
* JP11(1-2) open & JP11(3-4)
closed & JP11(5-6)closed: bus clock = 60MHz
* JP11(1-2) closed & JP11(3-4) open & JP11 (5-6) closed: bus clock =
66MHz
* JP9(1-2) open & JP9(3-4)open : multiplier = 1.5
* JP9(1-2) closed & JP9(3-4) open: multiplier = 2
* JP9(1-2)closed & JP9(3-4) closed: multplier =2.5
* JP9(1-2)open & JP9(3-4) closed: multiplier = 3
* JP9(1-2)open & JP9(3-4) open : multiplier = 3.5
b: CYRIX 6x86 tm / 6x86L tm CPU
CPU speed |
bus clock
& |
JP11 |
JP11 |
JP11 |
JP9 |
JP9 |
PR-133+ |
55MHz x 2 |
closed |
closed |
open |
closed |
open |
PR-150+ |
60MHz x 2 |
open |
closed |
closed |
closed |
open |
PR-166+ |
66MHz x 2 |
closed |
open |
closed |
closed |
open |
PR-200+ |
75MHz x 2 |
open |
closed |
open |
closed |
open |
c: CYRIX 6x86MX tm CPU
CPU speed |
bus clock
& |
JP11 |
JP11 |
JP11 |
JP9 |
JP9 |
PR-150+ - 120MHz |
60MHz x 2 |
open |
closed |
closed |
closed |
open |
PR-166+ - 133MHz |
66MHz x 2 |
closed |
open |
closed |
closed |
open |
PR-166+ - 150MHZ |
60MHz x 2.5 |
open |
closed |
closed |
closed |
closed |
PR-200+ - 150MHz |
75MHz x 2 |
open |
closed |
open |
closed |
open |
PR-200+ - 166MHz |
66MHz x 2.5 |
closed |
open |
closed |
closed |
closed |
PR-200+ - 180MHz |
60MHz x 3 |
open |
closed |
closed |
open |
closed |
PR-233+ - 188MHz |
75MHz x 2.5 |
open |
closed |
open |
closed |
closed |
PR-233+ - 200MHz |
66MHz x 3 |
closed |
open |
closed |
open |
closed |
PR-266+ - 233MHz |
66MHz x 3.5 |
closed |
open |
closed |
open |
open |
PR-266+ - 225MHz |
75MHz x 3 |
open |
closed |
open |
open |
closed |
d: AMD-K5 tm CPU
CPU speed |
JP11(1-2) |
JP11(3-4) |
JP11(5-6) |
JP9(1-2) |
JP(1-2) |
JP9(3-4) |
PR-90 |
open |
closed |
closed |
open |
open |
open |
PR-100 |
closed |
open |
closed |
open |
open |
open |
PR-120 |
open |
closed |
closed |
closed |
closed |
open |
PR-133 |
closed |
open |
closed |
closed |
closed |
open |
PR-166 |
closed |
open |
closed |
closed |
closed |
closed |
PR-200 |
closed |
open |
closed |
open |
open |
closed |
e: AMD-K6 tm CPU
CPU speed |
JP11(1-2) |
JP11(3-4) |
JP11(5-6) |
JP9(1-2) |
JP9(3-4) |
PR2-166 |
closed |
open |
closed |
closed |
closed |
PR2-200 |
closed |
open |
closed |
open |
closed |
PR2-233 |
closed |
open |
closed |
open |
open |
CONNECTORS
A: J15
pin |
assignment |
function |
pin |
assignment |
function |
1 |
speaker |
speaker |
14 |
+5V |
VCC |
2 |
NC |
15 |
ground |
VCC |
|
3 |
ground |
16 |
no connection |
NC |
|
4 |
+5V |
|
17 |
green control |
green |
5 |
power LED (+) |
power LED |
18 |
ground |
green |
6 |
no connection |
19 |
no connection |
NC |
|
7 |
ground |
20 |
HDD LED (-) |
HDD LED |
|
8 |
key lock |
21 |
HDD LED (+) |
HDD LED |
|
9 |
ground |
22 |
+5V |
IrDA connector |
|
10 |
power switch |
ATX power |
23 |
no connection |
IrDA |
11 |
standby voltage |
ATX power |
24 |
IRRX |
|
12 |
reset control |
reset |
25 |
ground |
|
13 |
ground |
reset |
26 |
IRTX |
B: J2 PS/2 mouse cable connector
pin no. |
assignment |
1 |
mouse data |
2 |
no connector |
3 |
ground |
4 |
+5V |
5 |
mouse clock |
C: J13 U.S.B. connector
pin no. |
assignment |
pin no. |
assignment |
A1 |
+5V |
B5 |
no connection |
A2 |
port 1 negative data |
B4 |
ground |
A3 |
port 1 positive data |
B3 |
port 2 positive data |
A4 |
ground |
B2 |
port 2 negative data |
A5 |
no connection |
B1 |
+5V |
D: J14 CPU cooling fan power connector (optional)
pin no. |
assignment |
1 |
ground |
2 |