MANUAIS DE MOTHERBOARDS BIOTEQ |
MB-8500TVD
JUMPER SETTING
A jumper is several pins which
may or may not be covered by a plastic
jumper cap. A jumper is used to select different system options.
A: JP5 cache RAM size selection
jumper no. |
256KB |
512KB |
JP5 |
open |
closed |
cache RAM combination
SRAM |
cache RAM |
tag RAM |
cacheable |
(U9,U10) |
U8 |
||
256KB |
(32K x 32) x 2pcs |
(8K x 8)/(32Kx8) x 1pc |
64 |
512KB |
(64K x 32) x 2pcs |
(32K x 8) x 1pc |
64 |
B: JP6 CMOS function selection
OPEN: to mantain set up data in
CMOS for normal functioning (default)
CLOSED: to clear CMOS setup memory, if there has been any inappropriate
incurring the system faillure.
Note: Please follow the procedure as below to clear BIOS
password if your
password is lost or forgotten.
power off -> JP6 closed -> power on for several seconds -> power off -> JP6open -> power on -> reset your desired password
C: JP15 R.T.C. battery
selection.
CLOSED: onboard battery enabled (default)
OPEN: onboard battery disabled
CPU INSTALLATION/JUMPER SETTING
A: JP10, JP11, JP12,JP13 CPU type selection
CPU type |
JP10 |
JP11 |
JP12 |
JP13 |
remark |
|
VI/O |
Vcore |
|||||
single voltage |
open |
1-3 |
open |
1-2 |
3.5V |
3.5V |
open |
1-3 |
closed |
1-2 |
3.45V |
3.45V |
|
dual voltage |
open |
open |
open |
2-3 |
3.5V |
2.8V |
open |
open |
closed |
2-3 |
3.45V |
2.8V |
|
closed |
open |
open |
2-3 |
3.5V |
2.6V |
|
closed |
open |
closed |
2-3 |
3.5V |
2.6V |
B: JP2,JP3,JP4,JP7,JP8 CPU clock selection
a: INTEL CPU
CPU speed |
bus clock
& |
JP2 |
JP3 |
JP4 |
JP7 |
JP8 |
75MHz |
50MHz x 1.5 |
closed |
closed |
closed |
open |
open |
90MHz |
60MHz x 1.5 |
open |
closed |
closed |
open |
open |
100MHz |
66MHz x 1.5 |
closed |
open |
closed |
open |
open |
120MHz |
60MHz x 2 |
open |
closed |
closed |
open |
closed |
133MHz |
66MHz x 2 |
closed |
open |
closed |
closed |
closed |
150MHz |
60MHz x 2.5 |
open |
closed |
closed |
closed |
closed |
166MHz |
66MHz x 2.5 |
closed |
open |
closed |
closed |
closed |
180MHz |
60MHz x 3 |
open |
closed |
closed |
closed |
open |
200MHz |
66MHz x 3 |
closed |
open |
closed |
closed |
open |
JP2 closed & JP3 closed
& JP4 closed : bus clock = 50MHz
JP2 open & JP3 closed & JP4 closed : bus clock = 60MHz
JP2 closed & JP3 open & JP4 closed : bus clock = 66MHz
JP7 open & JP8 open : multplier = 1.5
JP7 open & JP8 closed : multiplier = 2
JP7 closed & JP8 closed : multiplier = 2.5
JP7 closed & JP8 open : multiplier = 3
b: CYRIX 6x86tm CPU
CPU speed |
bus clock
& |
JP2 |
JP3 |
JP4 |
JP7 |
JP8 |
P-120+ |
50MHz x 2 |
closed |
closed |
closed |
open |
closed |
P-133+ |
55MHz x 2 |
closed |
closed |
open |
open |
closed |
P-150+ |
60MHz x 2 |
open |
closed |
closed |
open |
closed |
P-166+ |
66MHz x 2 |
closed |
open |
closed |
open |
closed |
JP2 closed & JP3 closed
& JP4 closed : bus clock = 50MHz
JP2 closed & JP3 closed & JP4 open : bus clock = 55MHz
JP2 open & JP3 closed & JP4 closed : bus clock = 60MHz
JP2 closed & JP3 open & JP4 closed : bus clock = 66MHz
JP7 open & JP8 closed : multiplier = 2
c: AMD-K5 tm CPU
CPU speed |
JP2 |
JP3 |
JP4 |
JP7 |
JP8 |
PR-75 |
closed |
closed |
closed |
open |
open |
PR-90 |
open |
closed |
closed |
open |
open |
PR-100 |
closed |
open |
closed |
open |
open |
PR-120 |
open |
closed |
closed |
open |
open |
PR-133 |
closed |
open |
closed |
open |
open |
PR-166 |
closed |
open |
closed |
closed |
closed |
PR-200 |
closed |
open |
closed |
closed |
open |
JP2 closed & JP3 closed
& JP4 closed : bus clock = 50MHz
JP2 closed & JP3 closed & JP4 open : bus clock = 55MHz
JP2 closed & JP3 open & JP4 closed : bus clock = 66 MHz
CONNECTORS
A: J14
pin |
assignment |
function |
pin |
assignment |
function |
1 |
speaker |
speaker |
14 |
NC |
NC |
2 |
NC |
15 |
NC |
NC |
|
3 |
ground |
16 |
no connection |
|
|
4 |
VCC |
17 |
green control |
green switch |
|
5 |
power LED(+) |
power LED |
18 |
ground |
green switch |
6 |
no connection |
power LED |
19 |
no connection |
NC |
7 |
ground |
20 |
HDD LED (-) |
HDD LED |
|
8 |
keylock |
21 |
HDD LED(+) |
HDD LED |
|
9 |
ground |
22 |
no connection |
NC |
|
10 |
turbo LED(-) |
turbo LED |
23 |
NC |
NC |
11 |
turbo LED(+) |
reset |
24 |
ground |
NC |
12 |
reset control |
25 |
VCC |
VCC ground |
|
13 |
ground |
reset |
26 |
ground |
VCC ground |
B: J10
U.S.B CONNECTOR
pin no. |
assignment |
pin no. |
assignment |
B1 |
+5V |
A5 |
no connection |
B2 |
USB-II positive data |
A4 |
ground |
B3 |
USB-II negative data |
A3 |
USB -I negative data |
B4 |
ground |
A2 |
USB-I positive data |
B5 |
No connection |
A1 |
+5V |
C: J12
CPU COOLER POWER CONNECTOR
pin no. |
assignment |
2 |
+12V |
1 |
ground |