5VIA5S
Jumper Setting

CPU frequency JCK ( JCK1, JCK2, JCK3 ) JP1 ( 1-2, 3-4, 5-6 ) Bus CLK Ratio
Intel 75Mhz 2-3, 2-3, 2-3 all open 50 1.5X
Intel 90Mhz 1-2, 1-2, 2-3 all open 60 1.5X
Intel 100Mhz 1-2, 1-2, 1-2 all open 66 1.5X
Intel 120Mhz 1-2, 1-2, 2-3 1-2 60 2.0X
Intel 133Mhz 1-2, 1-2, 1-2 1-2 66 2.0X
Intel 166Mhz 1-2, 1-2, 1-2 1-2, 3-4 66 2.5X
Intel 200Mhz 1-2, 1-2, 1-2 3-4 66 3.0X
Intel 233Mhz 1-2, 1-2, 1-2 all open 66 3.5X


CPU frequency JCK (JCK1, JCK2, JCK3) JP1 (1-2, 3-4, 5-6) Bus CLK Ratio
AMD K5-PR75 2-3, 2-3, 2-3 all open 50 1.5X
AMD K5-PR90 1-2, 1-2, 2-3 all open 60 1.5X
AMD K5-PR100 1-2, 1-2, 1-2 all open 66 1.5X
AMD K5-PR120 1-2, 1-2, 2-3 all open 60 1.5X
AMD K5-PR133 1-2, 1-2, 1-2 all open 66 1.5X
AMD K5-PR150 1-2, 1-2, 2-3 1-2, 3-4 60 2.5X
AMD K5-PR166 1-2, 1-2, 1-2 1-2, 3-4 66 2.5X
AMD K5-PR200 1-2, 1-2, 1-2 3-4 66 3.0X
AMD K6-PR166 1-2, 1-2, 1-2 1-2, 3-4 66 2.5X
AMD K6-PR200 1-2, 1-2, 1-2 3-4 66 3.0X
AMD K6-PR233 1-2, 1-2, 1-2 all open 66 3.5X

¡@

CPU frequency JCK (JCK1, JCK2, JCK3) JP1 (1-2, 3-4, 5-6) Bus CLK Ratio
Cyrix 6x86L-PR120+ 2-3, 2-3, 2-3 1-2 50 2.0X
Cyrix 6x86L-PR150+ 1-2, 1-2, 2-3 1-2 60 2.0X
Cyrix 6x86L-PR166+ 1-2, 1-2, 1-2 1-2 66 2.0X
Cyrix 6x86L-PR200+ 1-2, 2-3, 1-2 1-2 75 2.0X
Cyrix 6x86MX-PR166 1-2, 1-2, 2-3 1-2, 3-4 60 2.5X
Cyrix 6x86MX-PR200 1-2, 1-2, 1-2 1-2, 3-4 66 2.5X
Cyrix 6x86MX-PR200 1-2, 2-3, 1-2 1-2 75 2.0X
Cyrix 6x86MX-PR233 1-2, 2-3, 1-2 1-2, 3-4 75 2.5X
Cyrix 6x86MX-PR233 1-2, 1-2, 1-2 3-4 66 3.0X
Cyrix 6x86MX-PR266 1-2, 2-3, 1-2 3-4 75 3.0X
Cyrix 6x86MX-PR266 1-2, 1-2, 1-2 all open 66 3.5

¡@