5ALi61
Jumper Setting

¡@

Cpu power mode Example JP7
only 3.52v AMD-K5, Cyrix M1 1-2, 3-4, 5-6, 7-8
only 3.3v Intel Pentium 1-2, 5-6, 7-8
dual 3.2v & 3.3v AMD-K6-233 5-6, 7-8
dual 3.1v & 3.3v for future CPU 1-2, 3-4, 7-8
dual 2.9v & 3.3v AMD-K6 & Cyrix M2, IBM 6x86MX 1-2, 7-8
dual 2.8v & 3.3v IBM 6x86L, Intel Pentium 7-8
dual 2.5v & 3.3v for future CPU 1-2, 5-6
dual 2.2v & 3.45v or 3.3v AMD K6-2 266/300 3-4
dual 2.1v & 3.3v for future CPU 1-2
dual 2.0v & 3.3v for future CPU all open

¡@

Product name CPU speed Bus (Mhz) Multiplier JP1
Pentium MMX-166 166 66 2.5X 1-2, 3-4, 9-10, 11-12
Pentium MMX-200 200 66 3.0X 3-4, 9-10, 11-12
Pentium MMX-233 233 66 3.5X 9-10, 11-12
Pentium-90/AMD
K5-PR90/120
90 60 1.5X 7-8, 9-10, 11-12
Pentium-100/AMD
K5-PR100/133
100 66 1.5X 9-10, 11-12
Pentium-120/AMD
K5-PR150
120 60 2.0X 1-2, 7-8, 9-10, 11-12
Pentium-133 133 66 2.0X 1-2, 9-10, 11-12
Penitum-150 150 60 2.5X 1-2, 3-4, 7-8, 9-10,
11-12
Pentium-166/AMD K5-PR166 166 66 2.5X 1-2, 3-4, 9-10, 11-12
Pentium-180 180 60 3.0X 3-4, 7-8, 9-10, 11-12
Pentium-200 200 66 3.0X 3-4, 9-10, 11-12

¡@

Product name CPU speed Bus (Mhz) Multiplier JP1
AMD K6-200 200 100 2.0X 1-2
AMD K6-250 250 100 2.5X 1-2, 3-4
AMD K6-300 300 100 3.0X 3-4
AMD K6-350 350 100 3.5X all open
AMD K6-400 400 100 4.0X 1-2, 5-6
AMD K6-450 450 100 4.5X 1-2, 3-4, 5-6
AMD K6-500 500 100 5.0X 3-4, 5-6
AMD K6-166 166 66 2.5X 1-2, 3-4, 9-10, 11-12
AMD K6-200 200 66 3.0X 3-4, 9-10, 11-12
AMD K6-233 233 66 3.5X 9-10, 11-12
AMD K6-266 266 66 4.0X 1-2, 5-6, 9-10, 11-12
AMD K6-300 300 66 4.5X 1-2, 3-4, 5-6, 9-10, 11-12
AMD K6-333 333 66 5.0X 3-4, 5-6, 9-10, 11-12
AMD K6-333 333 95 3.5X 7-8

¡@

Product name CPU speed Bus (Mhz) Multiplier JP1
Cyrix M2-PR233 200 100 2.0X 1-2
Cyrix M2-PR333 250 100 2.5X 1-2, 3-4
Cyrix M2-PR350 300 100 3.0X 3-4
Cyrix M2-PR166 150 60 2.5X 1-2, 3-4, 7-8, 9-10, 11-12
Cyrix M2-PR166 133 66 2.0X 1-2, 9-10, 11-12
Cyrix M2-PR200 166 66 2.5X 1-2, 3-4, 9-10, 11-12
Cyrix M2-PR200 150 75 2.0X 1-2, 7-8, 9-10
Cyrix M2-PR233 188 75 2.5X 1-2, 3-4, 7-8, 9-10
Cyrix M2-PR233 166 83 2.0X 1-2, 9-10
Cyrix M2-PR266 208 83 2.5X 1-2, 3-4, 9-10
Cyrix MII-300 233 83 3.5X 9-10
Cyrix MII-300 225 75 3.0X 3-4, 7-8, 9-10
Cyrix MII-333 250 83 3.0X 3-4, 9-10
Cyrix MII-333 263 75 3.5X 7-8, 9-10
Cyrix MII-333 291 83 3.5X 9-10
Cyrix MII-350 300 75 4.0X 1-2, 5-6, 7-8, 9-10
6x86 P150+GP 120 60 2.0X 1-2, 7-8, 9-10, 11-12
6x86 P166+GP 133 66 2.0X 1-2, 9-10, 11-12
6x86 P200+GP 150 75 2.0X 1-2, 7-8, 9-10