Back to motherboard page

Home

Full Yes 82430TX Manual

 

CONTENTS

 

Chapter 1 ……………………………………………………………… 1

1. Introduction ………………………………………………………….…. 1

2. Specifications ….…………………………………………….………….. 2

Chapter 2 Hardware Configuration…………..………… 3

1. AT Layout Placement …………………..………………………….…… 3

2. ATX layout Placement ……………………………..…………….…….. 4

3. Jumper Setting ………………………………………………………….. 5

Flash ROM Type Voltage ………………………………………………. 5

DIMM Modules Voltage ……………………………………..………… 5

CMOS Clear Function Select …………………………………………… 5

CPU Clock Select …………………………………………………….… 5

CPU Vcore Frequency Ratio …………………………………….….…. 6

CPU Vcore Voltage Select ………………………………………….…. 6

Others Jumper Setting ………………………………………………….. 6

Connectors ………………………………………………………….….. 7

USB Connectors ………………………………………………….……. 7

FAN Device Connector …………………………………………….…... 8

CPU Quick Index 1 …………………..……………………………….…8

CPU Quick Index 2 …………………..……………………………….…9

 

Chapter 3 BIOS Setup……………………………………….…10

Section 1 Main Menu …………………………………………….…….10

Section 2 Standard CMOS Setup ………………………………………12

Section 3 BIOS Features Setup ……………………………………….. 13

Section 4 Supervisor/User Password Setting …………………………..15

Section 5 Chipset Setup/Integrated Peripherals Feature Setup .………...16

Section 6 Integrated Peripherals ………………………………………..19

Section 7 Power Management Setup …………………………………...22

Section 8 PnP/PCI Configuration Setup ………………………………..25

Section 9 Low-Level Format Utility …………………………….……...26

 

 

 

Chapter 1

1.Introduction

The 82430TX PCI consists of the TX System Controller (MTXC) and PCI ISA IDE Xcelerator (PIIX4). The PCIset forms a Host-to-PCI bridge and provides the second level cache control and a full function 64-bit data path to main memory. The MTXC integrates the cache and main memory DRAM control function and provides bus control to transfers between the CPU, cache, main memory, and the PCI Bus. The second level (L2) cache controller supports a write-back cache policy for cache size of 256 Kbytes and 512 Kbytes. Using the snoop ahead feature, the MTXC allows PCI masters to achieve full PCI bandwidth. For increased system performance, the MTXC integrates posted write and read prefetch buffers. The Intel 430TX PCIset integrates many Power Management features that will enable the system to save power whenever the system resources become idle.

The PCI ISA IDE Xcelerator (PIIX4) is a multi-function PCI device implementing a Universal Serial Bus host/hub function, and an Enhanced Power Management function. As a PCI-to-ISA bridge, the PIIX4 integrates many common I/O function found in ISA-based PC system—a seven channel DMA Controller, two 82C59 Interrupt Controllers, an 8254 Time/Counter, and a Real Time Clock. In addition to Compatible transfers, each DMA channel supports Type F transfers. The PIIX4 also contains full support for both PC/PCI and Distributed DMA protocols implementing PCI based DMA. The Interrupt Controller has Edge or Level sensitive Programmable inputs and fully supports the use of an external I/O Advanced Programmable Interrupt Controller (APIC) and Serial Interrupts. Chip select decoding is provides for BIOS, Real Time Clock, Keyboard Controller, second external Microcontroller, as well as 2 Programmable Chip Selects. The PIIX4 provides full Plug and Play compatibility. The PIIX4 can be configured as a Subtractive Decode bridge or as a Positive Decode bridge.

The PIIX4 supports two IDE connectors for up to four IDE device providing an interface for IDE hard disks and CDROMs. Up to four IDE device can be support in Bus Master mode. The PIIX4 contains support for "Ultra 33" synchronous DMA compatible devices.

PIIX4 contains a Universal Serial Bus (USB) Host Controller that is Universal Host Controller Interface (UHCI) compatible. The Host Controller’s root hub has two programmable USB ports.

The PIIX4 support Enhanced Power Management, including full Clock Control, Device Management for up to 14 devices, and Suspend and Resume logic with Power On Suspend. It fully support Operating System Directed Power Management via the Advanced Configuration and Power Interface (ACPI) specification. The PIIX4 integrates both a System Management Bus (SMBus) Host and Slave interface for communication with other Power Management peripherals.

 

 

 

2.Specifications

Intel 82430TX PCIsetsymbol 212 \f "Symbol" \s 10Ô}chipset

Support Intel Pentium ,MMX CPUs, Cyrix 6x86, 6x86L, and M2 CPUs, AMD K5, and K6 CPUs, and IDT C6 CPUs.

Support full range CPU’s frequency, from 90MHz to 233MHz

256KB or 512KB Pipeline Burst SRAM on board

Support Both Fast Page Mode and Extended Data Output (EDO) DRAM modules

Uses 72-pin SIMM modules X 4 and 168-pin DIMM modules X 2 auto banking in multiple configuration, the maximum on board MEMORY BANK is two.

Up to 256MB

Support SDRAM/EDO DRAM/FPM DRAM use 168-pin DIMM modules

4X PCI Local Bus slots, and 4X 16Bits ISA Bus slots

Up to four IDE device can be support in Bus Master mode

Support for "Ultra 33" synchronous DMA compatible device

Support the Universal Serial Bus (USB)

Support LS-120MB floppy disk

Support Microprocessor Thermal Management (Temperature Controller/ Fan Controller/ Melody)

Support ACPI(Advanced Configuration and Power Interface)

AWARD BIOS (Boot Block Flash ROM), Support "Plug and Play" function

Remote Ring On ( Modem on line)

Software Power-Off (Must be ATX Power Supply)

Dual Function Switch Button (Power Management Setup)

 

 

Chapter 2

Hardware Configuration

1. AT Layout placement(Intel 82430TX-A)

 

 

ATX Layout placement(Intel 82430TX-B)

 

 

3. Jumper Setting (* : default)

symbol 129 \f "Wingdings" \s 12}. JP3 Flash ROM Type Voltage (Factory)

+5V +12V
2 - 3 1 - 2

symbol 130 \f "Wingdings" \s 12‚}. J6,J7 DIMM Modules Voltage

+5V * +3.3V
1 - 2 2 - 3

symbol 131 \f "Wingdings" \s 12ƒ}. J15 CMOS Clear Function Select

* 1 - 2 I Internal Battery
2 - 3 Clear CMOS RAM data

Note: To clear CMOS setup memory if there has been any inappropriate operation incurring the system failure

symbol 132 \f "Wingdings" \s 12„}. CPU Clock Select

Clock(MHz) 55MHz 60MHz *66MHz 75MHz
JP2 OFF OFF OFF OFF
JP4 ON OFF OFF ON
JP5 ON ON OFF OFF

 

 

 

 

 

 

 

symbol 133 \f "Wingdings" \s 12…}.CPU Vcore Frequency Ratio

Frequency Ratio X1.5/X3.5 *X2 X2.5 X3
JP13 OFF 1 - 2 1-2, 3-4 3 - 4

 

 

 

 

symbol 134 \f "Wingdings" \s 12†}. CPU Vcore Voltage Select

CPU Voltage JP14
2.5V 1 - 2
2.8V 3 - 4
2.9V 5 - 6
3.2V 7 - 8
3.3V * 9 - 10
3.5V 11 - 12

 

symbol 135 \f "Wingdings" \s 12‡}. Others Jumper Setting

 

 

 

 

 

 

 

 

Pin No. Assignment Function Pin No. Assignment Function
1 IRRX

 

IR

16 HDD LED - HDD LED
2 GND   17 HDD LED -  
3 IRTX   18 HDD LED +  
4 +5V   19 GND RESET BUTTON
5 NC   20 RESET  
6 +5V   21 PWR LED +

POWER

LED &

KEYLOCK

7 GND   22 NC  
8 SB3V PS-ON 23 PWR LED -  
9 POWER-ON   24 KEYLOCK  
10 GND

SMI

SWITCH

25 GND  
11 EXTSMI   26 +5V SPEAKER
12 NC   27 NC  
13 SMI LED + SMI LED 28 NC  
14 SMI LED -   29 SPK OUT  
15 HDD LED +        

Note 1 : "PS-ON" is connect POWER ON-OFF switch of the "ATX" Power Supply

symbol 136 \f "Wingdings" \s 12ˆ}. Connectors

J1 Connector of ATX Power Supply
J4 Connector of AT Power Supply
CN2 PS/2 Mouse
CN3 Keyboard
CN1 Serial Port 1
CN5 Serial Port 2
CN4 Parallel Port
CN6 Ultra IDE 1
CN7 Ultra IDE 2
CN8 Floppy Driver Port

 

 

 

 

 

 

 

symbol 137 \f "Wingdings" \s 12‰}. CN10 Universal Serial Bus (USB) Connectors

Pin1 : +5V Pin2 : +5V

Pin3 : USBP1- Pin4 : USBP0-

Pin5 : USBP1+ Pin6 : USBP0+

Pin7 : GND Pin8 : GND

Pin9 : GND Pin10: GND

symbol 138 \f "Wingdings" \s 12Š}. FAN FAN Device Connector

Pin1 : GND

Pin2 : Fan Voltage (+12V)

Pin3 : GND

 

DRAM Installation :

* SIMM 1 & 2(BANK0) & DIMM5(BANK0) can not install simultaneously.

** SIMM 3 & 4(BANK1) & DIMM6(BANK1) can not install simultaneously.

 

symbol 243 \f "Monotype Sorts" \s 12ó}symbol 243 \f "Monotype Sorts" \s 12ó}symbol 243 \f "Monotype Sorts" \s 12ó}. CPU Quick Index 1.

INTEL CPU.

CPU TYPE PRINTING MUL/MHz JP13 JP2 JP4 JP5
Pentium 90 1.5/60 OFF OFF OFF ON
Pentium 100 1.5/66 OFF OFF OFF OFF
Pentium 120 2.0/60 1-2 OFF OFF ON
Pentium 133 2.0/66 1-2 OFF OFF OFF
Pentium 150 2.5/60 1-2,3-4 OFF OFF ON
Pentium/MMX 166 2.5/66 1-2,3-4 OFF OFF OFF
Pentium/MMX 200 3.0/66 3-4 OFF OFF OFF
Pentium MMX 233 3.5/66 OFF OFF OFF OFF

AMD CPU.

CPU TYPE PRINTING MUL/MHz JP13 JP2 JP4 JP5
AMD-K5 PR-90 1.5/60 OFF OFF OFF ON
AMD-K5 PR-100 1.5/66 OFF OFF OFF OFF
AMD-K5 PR-133 2.0/66 1-2 OFF OFF OFF
AMD-K5/K6 PR-166/PR2-166 2.5/66 1-2,3-4 OFF OFF OFF
AMD-K6 PR2-200 3.0/66 3-4 OFF OFF OFF
AMD-K6 PR2-233 3.5/66 OFF OFF OFF OFF

Cyrix ( IBM ) 6x86/6x86L

CPU TYPE PRINTING MUL/MHz JP13 JP2 JP4 JP5
6x86/6x86L PR-133+ 2.0/55 1-2 OFF ON ON
6x86/6x86L PR-150+ 2.0/60 1-2 OFF OFF ON
6x86/6x86L PR-166+ 2.0/66 1-2 OFF OFF OFF
6x86/6x86L PR-200+ 2.0/75 1-2 OFF ON OFF

symbol 243 \f "Monotype Sorts" \s 12ó}symbol 243 \f "Monotype Sorts" \s 12ó}symbol 243 \f "Monotype Sorts" \s 12ó}. CPU Quick Index 2.,

CPU Vcore Voltage Select

CPU Voltage JP14
2.5V 1 - 2
2.8V 3 - 4
2.9V 5 - 6
3.2V 7 - 8
3.3V * 9 - 10
3.5V 11 - 12

 

 

Note:

INTEL Pentium MMX/Cyrix 6x86L CPU Setting by 2.8V

AMD K6-166/200 Setting by 2.9V

AMD K6-233 Setting by3.2V

INTEL Pentium / AMD K5 CPU Setting 3.3V

AMD K5-166 Setting 3.52V

CYRIX 6x86 CPU Setting3.3V or 3.52V

 

 

 

 

Chapter 3

BIOS Setup

Starting Setup

While the BIOS is in control, the Setup program can be activated in one of two ways:

By pressing <Del> immediately after turn on the system, or

by pressing the <Del> key when the following message appears briefly at the bottom of the screen during the POST (Power On Self Test).

Section 1. Main Menu

Standard CMOS Setup

This setup page includes all the items in a standard, AT-compatible BIOS.

BIOS Features Setup

This setup page includes all the items of Award special enhanced features.

Supervisor/ User Password Setting

Change, set, or disable password. It allows you to limit access to the system and Setup, or just to Setup.

Chipset Features Setup

This setup page includes all the items of chipset special features.

 

Power Management Setup

This entry only appears if your system supports Power Management, "Green PC", standards.

PNP / PCI Configuration Setup

This entry appears if your system supports PNP / PCI.

Load BIOS Defaults

The BIOS defaults have been set by the manufacturer and represent settings which provide the minimum requirements for your system to operate.

Load Setup Defaults

The chipset defaults are settings which provide for maximum system performance. While Award has designed the custom BIOS to maximize performance, the manufacturer has the right to change these defaults to meet their needs.

Integrated Peripherals

This section page includes all the items of IDE hard drive and Programmed Input / Output features.

IDE HDD Auto Detection

Automatically detect and configure hard disk parameters. The Award BIOS includes this ability in the event you are uncertain of your hard disk parameters.

HDD Low Level Format

If supported by your system, this provides a hard disk low level format utility.

Save & Exit Setup

Save CMOS changes to CMOS and exit setup.

Exit Without Save

Abandon all CMOS changes and exit setup.

 

 

 

Section 2. Standard CMOS Setup

Date

The date format is <day>, <date> <month> <year>.

Time

The time format is <hour> <minute> <second>. The time is calculated based on the 24-hour military-time clock. For example, 1 p.m. is 13:00:00.

Primary Master/Primary Slave/Secondary Master/Secondary Slave

Press PgUp or PgDn to select a numbered hard disk type or type the number and press <Enter>. Note that the specifications of your drive must match with the drive table. The hard disk will not work properly if you enter improper information for this category. If your hard disk drive type is not matched or listed, you can use Type "User" to define your own drive type manually.

If you select Type "User", you will need to know the listed information. Enter the information directly from the keyboard and press <Enter>. This information should be included in the documentation from your hard disk vendor or the system manufacturer.

If the controller of HDD interface is ESDI, the selection shall be "Type 1".

If the controller of HDD interface is SCSI, the selection shall be "None".

If you select Type "Auto", BIOS will Auto-Detect the HDD & CD-ROM Drive at the POST stage and showing the IDE for HDD & CD-ROM Drive.

If a hard disk has not been installed select NONE and press <Enter>.

Drive A Type / Drive B Type

The category identifies the types of floppy disk drive A or drive B that have been installed in the computer.

Choose : None, 360K, 1.2M, 720K, 1.44M, 2.88M

Video

The category selects the type of video adapter used for the primary system monitor. Although secondary monitors are supported, you do not have to select the type in Setup.

Choose : EGA/VGA, CGA40, CGA80, MONO

Halt On

The category determines whether the computer will stop if an error is detected during power up.

Memory

The category is display-only which is determined by POST (Power On Self Test) of the BIOS.

Section 3. BIOS Features Setup

Virus Warning

When this item is enabled, the Award BIOS will monitor the boot sector and partition table of the hard disk drive for any attempt at modification. If an attempt is made, the BIOS will halt the system and the following error message will appear. Afterwards, if necessary, you will be able to run an anti-virus program to locate and remove the problem before any damage is done. (default: Disabled)

! WARNING !

Disk boot sector is to be modified

Type "Y" to accept write or "N" to abort write

Award Software, Inc.

NOTE: Many disk diagnostic programs which attempt to access the boot sector table can cause the above warning message. If you will be running such a program, we recommend that you first disable Virus Protection beforehand.

CPU Internal Cache/External Cache

Enabled Enable cache (default)
Disabled Disable cache

Quick Power On Self Test

Enabled Enable quick POST (default)
Disabled Normal POST

Boot Sequence

Choose : A,C,SCSI (default) C,A,SCSI C,CDROM,A

CDROM,C,A D,A,SCSI E,A,SCSI F,A,SCSI

SCSI,A,C SCSI,C,A C only LS/ZIP,C

Swap Floppy Drive

This item allows you to determine whether enable the swap floppy drive or not. If enable, Floppy A: as B: and B: as A:

The choice: Enabled /Disabled(default).

Boot Up Floppy Seek

During POST, BIOS will determine if the floppy disk drive installed is 40 or 80 tracks. 360K type is 40 tracks while 760K, 1.2M and 1.44M are all 80 tracks. (default: Enabled)

Boot Up NumLock Status

On Keypad is number keys (default)
Off Keypad is arrow keys

Boot Up System Speed

High Set the speed to high (default)
Low Set the speed to low

Typematic Rate Setting

Enabled Enable typematic rate
Disabled Disable typematic rate (default)

Typematic Rate (Chars/Sec)

6,8,10,..,30 "n" characters per second (default:6)

TypematicDelay (Msec)

250,500,750,1000 "n" msec (default:250)

PS/2 Mouse Function Control

Enabled Enable PS/2 Mouse (default)
Disabled Disable PS/2 Mouse

Security Option

System The system will not boot and access to Setup will be denied if the correct password is not entered at the prompt.
Setup The system will boot, but access to Setup will be denied if the correct password is not entered at the prompt. (default)

Note: To disable security, select PASSWORD SETTING at Main Menu and then you will be asked to enter password. Do not type anything and just press <Enter>, it will disable security. Once the security is disabled, the system will boot and you can enter Setup freely.

OS Select for DRAM > 64MB

This item allows you to access the memory that over 64MB in OS/2.

The choice: Non-OS2 (default), OS2.

PCI / VGA Palette Snoop

Enabled When PCI/VGA working with MPEG ISA/VESA VGA Card.
Disabled When PCI/VGA not working with MPEG ISA/VESA VGA Card. (default)

Video BIOS Shadow

Enabled Video shadow is enabled (default)
Disabled Video shadow is disabled

C8000 - CBFFF Shadow/DC000 - DFFFF Shadow

Enabled Optional shadow is enabled
Disabled Optional shadow is disabled (default)

 

Assign IRQ For VGA

Enabled IRQ is enabled for VGA card
Disabled IRQ is disabled for VGA card (default)

 

Section 4. Supervisor/User

Password Setting

You can set either supervisor or user password, or both of then. The differences between are:

supervisor password : can enter and change the options of the setup menus.

user password : just can only enter but do not have the right to change

the options of the setup menus.

When you select this function, the following message will appear at the center of the screen to assist you in creating a password.

ENTER PASSWORD:

Type the password, up to eight characters in length, and press <Enter>. The password typed now will clear any previously entered password from CMOS memory. You will be asked to confirm the password. Type the password again and press <Enter>. You may also press <Esc> to abort the selection and not enter a password.

To disable a password, just press <Enter> when you are prompted to enter the password. A message will confirm the password will be disabled. Once the password is disabled, the system will boot and you can enter Setup freely.

PASSWORD DISABLED.

When a password has been enabled, you will be prompted to enter it every time you try to enter Setup. This prevents an unauthorized person from changing any part of your system configuration.

Additionally, when a password is enabled, you can also require the BIOS to request a password every time your system is rebooted. This would prevent unauthorized use of your computer.

You determine when the password is required within the BIOS Features Setup Menu and its Security option (see Section 3). If the Security option is set to "System", the password will be required both at boot and at entry to Setup. If set to "Setup", prompting only occurs when trying to enter Setup.

Section 5. Chipset Setup/Integrated Peripherals Features Setup

Auto Configuration

Pre-defined values for DRAM, cache timing according to CPU type & system clock.

The Choice: Enabled (default), Disabled.

Note: When this item is enabled, the pre-defined items will become SHOW- ONLY.

DRAM Timing

The DRAM timing is controlled by the DRAM Timing Registers. The timings programmed into this register are dependent on the system design. Slower rates may be required in certain system designs to support loose layouts or slower memory.

60ns DRAM Timing Type.
70ns DRAM Timing Type. (default)

DRAM Leadoff Timing

This sets the number of CPU clocks allowed before reads and writes to DRAM are performed.

Choose : 11/7/3, 10/6/3, 11/7/4, 10/6/4

DRAM Read Burst <EDO/FPM>

This sets the timing for burst mode reads from two different DRAM(EDO/FPM). Burst read and write requests are generated by the CPU in four separate parts. The first part provides the location within the DRAM where the read or write is to take place while the remaining three parts provide the actual data. The lower the timing numbers, the faster the system will address memory.

x222/x333 Read DRAM (EDO/FPM) timings are 2-2-2/3-3-3
x333/x444 Read DRAM (EDO/FPM) timings are 3-3-3/4-4-4
x444/x444 Read DRAM (EDO/FPM) timings are 4-4-4/4-4-4

DRAM Write Burst Timing

This sets the timing for burst mode writes from DRAM. Burst read and write requests are generated by the CPU in four separate parts. The first part provides the location within the DRAM where the read or write is to take place while the remaining three parts provide the actual data. The lower the timing numbers, the faster the system will address memory.

x222 Write DRAM timings are 2-2-2-2
x333 Write DRAM timings are 3-3-3-3
x444 Write DRAM timings are 4-4-4-4

Fast EDO Lead Off

The item allows you to select the Fast EDO Lead Off or not to enhance the performance.

The Choice: Enabled, Disabled.

Refresh RAS# Assertion

This item allows you to select the type of DRAM refresh clock delay.

4,5Clks The timing type.

Fast RAS To CAS Delay

This field lets you insert a timing delay to get a faster performance between the Row Address Strobe (RAS) to Column Address Strobe (CAS) strobe signals, used when DRAM is written to, read from, or refreshed.

2,3 The timing delay

DRAM Page Idle Timer

This item allows you to select the type of DRAM Page Idle Timer delay.

2,4,6,8Clks The timing type (default: 2 Clks)

DRAM Enhanced Paging

This item allows you to determine whether to keep the page open until a page/row miss or use additional information to keep the DRAM page open when host may be "Light back".

The Choice: Enabled (default), Disabled.

Fast MA to RAS# Delay

This item allows you to select the DRAM Row Miss timing. Note: the timing adjustments are independent of DLT timing adjustment.

1 One clock. (MA setup to RAS# assertion)
2 Two clocks. (default)

SDRAM (CAS Lat / RAS -to-CAS)

This item allows you to select the CAS# latency for all SDRAM cycles and RAS# to CAS# delay.

2/2,3/3 The timing type. (default:3/3)

SDRAM Speculative Read

This item is capable of allowing a DRAM read request to be generated slightly before the address has been fully decoded. This can reduce all read latencies.

More simply, the CPU will issue a read request and included with this request is the place (address) in memory where the desired data is to be found. This request is received by the DRAM controller. When it is enabled, the controller will issue the read command slightly before it has finished determining the address.

The Choice: Enabled, Disabled (default).

System/Video BIOS Cacheable

Allow the System/Video BIOS to be cached to allow faster execution.

The Choice: Enabled, Disabled (default).

8 Bit I/O Recovery Time

The recovery time is the length of time, measured in CPU clocks, which the system will delay after the completion of an input/output request. This delay takes place because the CPU is operating so much faster than the input/output bus that the CPU must be delayed to allow for the completion of the I/O.

This item allows you to determine the recovery time allowed for 8 bit I/O. Choices are from NA, 1 to 8 CPU clocks.

16 Bit I/O Recovery Time

This item allows you to determine the recovery time allowed for 16 bit I/O. Choices are from NA, 1 to 4 CPU clocks.

Memory Hole At 15M-16M

In order to improve performance, certain space in memory can be reserved for ISA cards. This memory must be mapped into the memory space below 16 MB.

Enabled Memory hole supported.
Disabled Memory hole not supported. (default)

PCI 2.1 Compliance

Enabled With PCI 2.1 interface card.
Disabled Normal PCI interface card. (default)

Note : Most the PCI cards are for PCI V2.0.

 

 

Section 6. Integrated Peripherals

IDE HDD Block Mode

Enabled IDE controller uses block mode. (default)
Disabled IDE controller uses standard mode.

IDE PIO

IDE hard drive controllers can support up to two separate hard drives. These drives have a master/slave relationship which are determined by the cabling configuration used to attach them to the controller. Your system supports two IDE controllers--a primary and a secondary--so you have to ability to install up to four separate hard disks.

PIO means Programmed Input/ Output. Rather than have the BIOS issue a series of commands to effect a transfer to or from the disk drive, PIO allows the BIOS to tell the controller what it wants and then let the controller and the CPU perform the complete task by themselves. This simpler and more efficient (and faster).

Your system supports five modes, numbered from 0 (default) to 4, which primarily differ in timing. When Auto is selected, the BIOS will select the best available mode. This is true for the next four setup items:

IDE Primary Master PIO

IDE Primary Slave PIO

IDE Secondary Master PIO

IDE Secondary Slave PIO

IDE UDMA

Auto Ultra DMA is auto detect. (default)
Disabled Ultra DMA is Disabled.

On-Chip Primary PCI IDE

Enabled Primary HDD controller used. (default)
Disabled Primary HDD controller not used.

On-Chip Secondary PCI IDE

Enabled Secondary HDD controller used. (default)
Disabled Secondary HDD controller not used.

USB Keyboard Support

Choice are Enabled, Disabled. (default)

 

Onboard FDC Controller

Choices: Enabled (default), Disabled.

Onboard Serial Port 1/Port 2

Choices are 3F8/IRQ4, 2F8/IRQ3, 3E8/IRQ4, 2F8/IRQ3, Auto, Disabled.

UR 2 Mode

Port 1: (default:3F8/IRQ4), Port 2: (default:2F8/IRQ3)

Choices are Normal (default), IrDA, ASKIR.

UR2 Duplex Mode

This item allows you to select the IR function when your select the UART 2 Mode is ASKIR

Choices are Half, Full.

Use UART2 Pins

This item allows you to determine the active of RXD, TXD.

Choices are IR-RX2TX2, RXD2 TXD2

Note: The IR-RX2TX2 select IR or Uart2 only one in hardware

Onboard Parallel Port

This item allows you to determine access onboard parallel port controller with which I/O address.

Choices are 378H/IRQ7 (default), 278H/IRQ5, 3BCH/IRQ7, Disabled.

Parallel Port Mode

Select an operating mode for the onboard parallel (printer) port. Normal EPP (Extended Parallel Port) ECP (Extended Capabilities Port) ECP+EPP PC AT parallel port Bi-directional port Fast, buffered port Fast, buffered, bi-directional port.

Select Normal unless you are certain your hardware and software both support EPP or ECP mode.

Choices are PS/2, EPP1.9, ECP, ECPEPP1.9, SPP (default), EPP1.7, ECPEPP1.7

ECP Mode Use DMA

Select a DMA channel for the parallel port for use during ECP mode.

Choices are 3, 1.

 

 

 

 

 

 

 

 

 

 

Section 7. Power Management Setup

Power Management

This category allows you to select the type (or degree) of power saving and is directly related to the following modes:

1. Doze Mode

2. Standby Mode

3. Suspend Mode4

4. HDD Power Down

There are four selections for Power Management, three of which have fixed mode settings.

Disable No power management. Disables all four modes
Min. Power Saving Minimum power management. Doze Mode = 1 hr. Standby Mode = 1 hr., Suspend Mode = 1 hr., and HDD Power Down = 15 min.
Max. Power Saving Maximum power management -- ONLY AVAILABLE FOR SL CPU. Doze Mode = 1 min., Standby Mode = 1 min., Suspend Mode = 1 min., and HDD Power Down = 1 min.
User Define (default) Allows you to set each mode individually. When not disabled, each of the ranges are from 1 min. to 1 hr. except for HDD Power Down which ranges from 1 min. to 15 min. and disable.

PM Control APM

When enabled, an Advanced Power Management device will be activated to enhance the Max. Power Saving mode and stop the CPU internal clock.

If the Max. Power Saving is not enabled, this will be preset to No.

Video Off Method

This determines the manner in which the monitor is blanked.

V/H SYNC+Blank (default) This selection will cause the system to turn off the vertical and horizontal synchronization ports and write blanks to the video buffer.
Blank Screen This option only writes blanks to the video buffer.
DPMS Initial display power management signaling.

VIDEO Off After

This item determines the Video Off timer.

The choice: Suspend, Standby(default), Doze, N/A

PM Timers

The following four modes are Green PC power saving functions which are only user configurable when User Defined Power Management has been selected. See above for available selections.

Doze Mode

When enabled and after the set time of system inactivity, the CPU clock will run at slower speed while all other devices still operate at full speed.

Standby Mode

When enabled and after the set time of system inactivity, the fixed disk drive and the video would be shut off while all other devices still operate at full speed.

Suspend Mode

When enabled and after the set time of system inactivity, all devices except the CPU will be shut off.

HDD Power Down

When enabled and after the set time of system inactivity, the hard disk drive will be powered down while all other devices remain active.

Throttle Duty Cycle

The duty cycle for CPU clock thermal mode

The choice: 12.5%, 25.0%, 37.5%, 50.0%, 62.5%(default), 75.0%, 87.5%

ZZ Active in Suspend

SRAM ZZ mode for L2 power management during CPU Standby. The choice: Enabled, Disabled(default)

VGA Active Monitor

The choice: Enabled(default), Disabled

Soft-Off by PWR-BTTN

Delay 4 Sec. Shut-off the system must delay 4 second for PS-ON Button
Instant-Off (default) Shut-off the system for one touch

Note: "PS-ON" button is for ATX POWER only

CPUFAN Off In Suspend

Component name is FAN for CPU fan use. The fan is stop when Suspend mode is active. (default: Enabled)

Resume by Ring

The Ring signal into the MODEM, than the system is restart. (default: Enabled)

Break Event From Suspend

IRQ 8 Clock Event

The choice: Enabled, Disabled (default)

Reload Global Timer Events

Power Down and Resume events are I/O events whose occurrence can prevent the system from entering a power saving mode or can awaken the system from such a mode. In effect, the system remains alert for anything which occurs to a device which is configured as On, even when the system is in a power down

Section 8. PnP/PCI Configuration Setup

 

PNP OS Installed

This item allows you to determine install PnP OS or not.

Choices are Yes(default) and No.

Resource Controlled by

The Award Plug and Play BIOS has the capacity to automatically configure all of the boot and Plug and Play compatible devices. However, this capability means absolutely nothing unless you are using a Plug and Play operating system such as Windowssymbol 226 \f "Symbol" \s 10â} 95.

Choices are Auto(default) and Manual.

Reset Configuration Data

This item allows you to determine reset the configuration data or not.

Choices are Enabled and Disabled(default).

IRQ3/4/5/7/9/10/11/12/14/15, DMA0/1/3/5/6/7 assigned to

 

This item allows you to determine the IRQ / DMA assigned to the ISA bus and is not available to any PCI slot.

Choices are Legacy ISA and PCI/ISA PnP.

PCI IDE IRQ Map to, Primary IDE INT#, Secondary IDE INT#

This allows you to configure your system to the type of IDE disk controller in use. By default, Setup assumes that your controller is an ISA (Industry Standard Architecture) device rather than a PCI controller. The more apparent difference is the type of slot being used.

If you have equipped your system with a PCI controller, changing this allows you to specify which slot has the controller and which PCI interrupt (A, B,C or D) is associated with the connected hard drives.

Remember that this setting refers to the hard disk drive itself, rather than individual partitions. Since each IDE controller supports two separate hard drives, you can select the INT# for each. Again, you will note that the primary has a lower interrupt than the secondary as described in "Slot x Using INT#" above.

Selecting "PCI Auto" allows the system to automatically determine how your IDE disk system is configured.

Used MEM base addr

This item allows you to determine which basic addresses do not be occupied by PCI Card and leave these addresses for some special ISA Card used only.

Choices are C800, CC00, D000, D400, D800, DC00.

Used MEM Length

This item determines the memory length of addresses which is for some special ISA Card used.

Choices are 8K, 16K , 32K, 64K.

Section 9. Low-Level Format Utility

 

 

 

 

 

 

 

 

SELECT DRIVE

Select from installed hard disk drive C or D. Listed at the bottom of the screen is the drive automatically detected by the utility.

BAD TRACK LIST

Auto Scan Bad Track

The utility will automatically scan bad tracks and list the bad tracks in the window at the right side of the screen.

Add Bad Track

Directly type in any information about known bad tracks in the window at the right side of the screen.

Modify Bad Track

Modify information about the added bad tracks in the window at the right side of the screen.

Delete Bad Track

Delete the added bad tracks in the window at the right side of the screen.

Clear Bad Track Table

Clear the whole bad track list in the window at the right side of the screen.


PREFORMAT

Interleave

Select the interleave number of the hard disk drive you wish to perform low level format. You may select from 1 to 8. Check the documentation that came with the drive for the correct interleave number, or select 0 for utility automatic detection.

Auto Scan Bad Track

This allows the utility to scan for bad sectors first then format by each track.

Start

Press <Y> to start low level format.