SET CPU VOLTAGE
TYPE/JUMPER | |||
QUICK TO SETTING FOR CYRIX 6X86 CPU CLK & VOLTAGE
(1) CPU CLK
Product name | CPU speed | Bus speed | Jumper JP6 | Multiplier |
6X86-P120-GP | 100 | 50 | 3-4, 7-8, 9-10 | 2X |
6X86-P133-GP | 110 | 55 | 3-4, 7-8 | 2X |
6X86-P150-GP | 120 | 60 | 3-4, 9-10 | 2X |
6X86-P166-GP | 133 | 66 | 3-4 | 2X |
6X86-P200-GP | 150 | 75 | 3-4, 5-6 | 2X |
JP6: SET CPU CLK AND FREQUENCY /RATIO
JP6(1-2,3-4) They are used to set CPU | JP6(5-6,7-8,9-10) They are used to set CPU CLK | ||
- | 1.5X and 3.5X | 7-8, 9-10 | 50 |
3-4 | 2X | 7-8 | 55 |
1-2, 3-4 | 2.5X | 9-10 | 60 |
1-2 | 3X | 66 | |
- | 5-6 | 75 |
INSTALL 586 CPU
QUICK TO SETTING FOR INTEL PENTIUM MMX CLK & VOLTAGE
CPU CLK
Product Name | CPU Speed (MHZ) | BUS CLK (MHZ) | JP6 | Multiplier |
PENTIUM-75 AMD-K5-PR75 | 75 | 50 | 7-8, 9-10 | 1.5X |
PENTIUM-90 AMD-K5-PR90 AMD-K5-PR120 | 90 | 60 | 9-10 | 1.5X |
PENTIUM-100 AMD-K5-PR100 AMD-K5-PR133 | 100 | 66 | all open | 1.5X |
PENTIUM-120 AMD-K5-PR150 | 120 | 60 | 3-4, 9-10 | 2X |
PENTIUM-133 AMD-K5-PR166 | 133 | 66 | 3-4 | 2X |
PENTIUM-150 | 150 | 60 | 1-2, 3-4, 9-10 | 2.5X |
PENTIUM-166 PENTIUM-MMX-166 AMD K6-166 | 166 | 66 | 1-2, 3-4 | 2.5X |
PENTIUM-180 | 180 | 60 | 1-2, 9-10 | 3X |
PENTIUM-200 PENTIUM-MMX-200 AMD K6-200 | 200 | 66 | 1-2 | 3X |
PENTIUM-MMX-233 AMD K6-233 | 233 | 66 | all open | 3.5X |